Service Mode
5
4
3
2
1
6
D
C
A
B
D
C
A
B
5
4
3
2
1
6
VSX-330
[2] Reset mode for numbers of protection detections
[Purpose]
[Basic operations]
FL Display
Description of Indications
Key Operation
(STANDBY state)
[ALC/STANDARD SURR]
+ [STANDBY/ON] keys
(press and hold the keys
for 10 seconds.)
(Counter Clear end)
[ENTER] key
(Normal display)
5 (-> normal) *1
5 (-> normal) *1
usually
*2
Time (sec.)
For clearing all the counts of protection detections.
(This mode resets the counts of protection detections.)
1. When the procedures for Reset mode for numbers of protection detections are completed, all the counters will be
reset to "000."
2. Prohibitions:
The protection detection counts cannot be cleared (reset to 000) with the MEMORY CLEAR process.
They can only be cleared when the procedures of Reset mode are completed.
*1 "5 (-> normal)" denotes that the display will return to the normal indication when no key operation is performed
for 5 seconds.
*2 Indication when the BD function is selected
[How to enter/exit]
During Standby mode, simultaneously press and hold the [ALC/STANDARD SURR] and [STANDBY/ON] keys
for 10 seconds to enter this mode.
The display will return to the normal indication when no key operation is performed for 5 seconds.
[Detailed explanations]