background image

 

8

floor

floor

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

To determine the desired viewing height, use the center slot opening in the wall mount as a center reference for the plasma television when mounted.  Once the height is determined, 
use the bubble level to insure that the bracket is level.  Next, using a pencil, mark the four (4) lag bolt slot openings on the mounting bracket. Before continuing, confirm the marks are 
located on the center of the studs.   
Drill 1/4" pilot holes on the four (4) markings on the wall. Raise the flat back plate and have someone hold it in place (

arrow side away from the wall and pointing up

).  

 Put the lag bolt through the flat washers. Screw the lag bolt through the upper left slot opening into the 1/4" pilot hole.  Confirm that the wall mount is still leveled and then screw a lag 
bolt to the upper right side slot opening into the 1/4" pilot hole.  Then install the remaining two lag bolts tightly into the wall studs in the lower left and right slot openings on the wall 
mount. Lateral movement of approximately 1½" for final positioning is now possible.  Make any positioning changes then secure the lag bolts.

 

See fig 4.

 

 

Wood studs behind 

the wall structure 

Drill gun with a 1/4" 

drill bit 

Wall structure 

Marking on wall 

Flat washers 

5/16" Lag bolts 

Access holes 

PDB-UWFB 

(back plate) 

Electrical  

Step 4 

All electrical wiring components should be installed at this time to ensure that the plasma display has enough power sources. 

Note: 

Pre drill before the securing the 

5/16" lag bolts. 

Caution: 

Do not over tighten the 5/16" lag bolts 

Center of 

viewing marks 

Summary of Contents for PDWB-5003

Page 1: ...PLASMA DISPLAY MOUNT MODEL INSTALLATION MANUAL VISIT US AT WWW PREMIERMOUNTS COM 3130 E Miraloma Ave Anaheim CA 92806 Phone 800 368 9700 Fax 800 832 4888 For service and parts contact ...

Page 2: ...fety precautions o Mount diagrams o Parts List o Optional Adapters o Installing the mounting bracket o Installing the mount o Electrical o Securing the mount o Checking for proper safety and security Contents ...

Page 3: ...all must always support the weight or load of the plasma Always conform the center of the wood stud before beginning the installation Do not install in locations where there is vibration movement or danger of impact Failure to do so could result in plasma cracking or falling from the wall causing damage and injury Do not install near heater fireplace direct sunlight or air conditioning or any othe...

Page 4: ...UNT MOUNTING BRACKET PART PDB UWFB MATERIAL 12 GA CRS COLOR Black powder coat A Lag bolt access slot B Mounting points 4 5 used on installations other than wall mounting C Access hole for power or cables D M6 security screw mounting points used on installations other than flat wall mounting PART Mounting bracket MATERIAL 12 GA P O COLOR Black Powder coat Mount Diagrams ...

Page 5: ...ceiling adapter adjustable range 24 to 46 QTY SIZE DESCRIPTION 4 5 16 Dia Lag bolts flat washers 1 Mounting bracket 1 PDB UWFB back plate 2 M6 x 12 mm Phillip security screws Used for additional security on mobile carts floor stands and ceiling mounts 1 Installations instructions 6 M8 x 20 Phillip screws Mount hardware Parts List TOOLS SUPPLY NEEDED CEILING ADAPTERS OPTIONAL HARDWARE LIST PSA 1 He...

Page 6: ...back of the plasma display align the mounting holes from the mounting bracket to the holes on the plasma display Arrow found on the mount must always be pointing to the top of the plasma display before securing it to the plasma display Loosely install the six 6 M8 x 20 Phillip screws to the plasma then secure the screws with a Phillips screwdriver CAUTION Do not over tighten the M8 x 20 Phillips s...

Page 7: ...ll using a commercially available stud finder and mark the center of the studs when found Set the mounting bracket to the wall and mark the desired height by marking the center of the Flat back plate See fig 3 Wall structure Wood studs behind the wall structure Stud centers marking Universal flat mount Adjusting the mount Desired height marking Installing the mounts CENTER OF VIEWING HEIGHT ...

Page 8: ...opening into the 1 4 pilot hole Confirm that the wall mount is still leveled and then screw a lag bolt to the upper right side slot opening into the 1 4 pilot hole Then install the remaining two lag bolts tightly into the wall studs in the lower left and right slot openings on the wall mount Lateral movement of approximately 1 for final positioning is now possible Make any positioning changes then...

Page 9: ...ogether Make sure all 4 tab openings are interlocked with the receiving tabs before letting go of the plasma See fig 5 Plasma display Mounting bracket Flat back plate 4 Securing tabs 4 Tab openings Wall structure Plasma display Wall structure Align all four 4 tab openings to the flat back plate receiving tabs and push the plasma as shown on arrows to lock in place Caution The plasma display is hea...

Reviews: