52
PDU-50WX2
Input Signal
Adjusting Point
Adjusting Method
White 100%
X-SUS-B, Y-SUS-B Adjustment
Set to the specified value with XSB and YSB of RS-232C command.
(Refer to "Timing adjustment of control signal of X and Y Drive Assys".)
Input Signal
Adjusting Point
Adjusting Method
White 100%
VR3701 (VRN)
(X DRIVE Assy)
VRN (minus reset voltage adjustment)
Adjust so that the voltage between K3707 (VRN) and K3702 (SUS-GND) becomes
-300V
±
1.0V.
Input Signal
Adjusting Point
Adjusting Method
Reference : Adjustment values using the Media color-difference meter (A-100)
1.Transmit RS-232C command "M 04", and display mask pattern 4.
2.Read adjusted value with "GPW", and adjust it with "PR H" ... "PBL".
3.Transmit "M 00", and mask off.
Sustain Pulse Waveform Adjustment
VRN Voltage Adjustment
Panel White Balance Adjustment
MASK Left Side
x
295
y
306
MASK Right Side
291
300