46
PDU-50WX2
INTERFACE Assy
Junction Connector
CN4007 (100P)
CN4010 (14P)
S4001
S4001
CN4005 (10P)
CN4009 (8P)
Connector Pin Arrangement
List of use connector, housing and recommended connection cable
Ref No.
PCB Connector
Housing
Contact
Recommended
Lead-wire
1
CN4007
Digital signal input
FX2B-100PA-1.27DSL FX2B-100SA-1.27R
AWG#28
2
CN4010
Sync. signal input
S14B-XASK-1
XAP-14V-1
SXA-001T-P0.6
AWG#24
3
CN4005
Power supply terminal
S10B-XASK-1
XAP-10V-1
SXA-001T-P0.6
AWG#24
4
Junction connector
AC power input
ELR-03V
ELP-03V
B8B-PH-SM3
PHR-8
SLF-41T-P1.3E
AWG#20 (105
°
C)
5
CN4009
RS-232C
Use Connector Position
Switch of POWER ON/STANDBY
is possible with S4001 on the
INTERFACE Assy.
At arrow (
‘
) direction:
Position in the normal use
At reverse direction:
Forced power on (Note)
Note:
When there are not jig for POWER
ON/STANDBY control or RS-232C
control, can perform power on by
the single module forcibly.
Please set a position at the direction
of arrow (
‘
) on the PCB silk in
normal use by all means.