PDP-505HD
82
K751Hi
K804Hi
K801Hi
K854Hi
K3607Hi
K3704Hi
D3751 Anode is
High.
VH UVP
VRN OVP
VRN UVP
IC5V OVP
12V OCP
RESET OCP
DRIVE STOP
P.D.
Drive section (drive control signals
& drive signal output elements) in
normal operation.
VH D/D Conv.Block in normal
operation
Scan Module in normal
operation.
Drive section (drive control signals
& drive signal output elements) in
normal operation.
VRN D/D Conv. Block in normal
operation.
Output voltage of IC3606, 3607,
3608 are normal
Output voltage of IC3606, 3607,
3608 are abnormal.
Y DRIVE Assy
VH D/D CONV. BLOCK
SCAN MODULE
Y DRIVE Assy
IC5V D/D CONV. BLOCK
Y DRIVE Assy
VRN D/D CONV. BLOCK
Y DRIVE Assy
VRN D/D CONV. BLOCK
YDRIVE Assy
SUS_MSK BLOCK
Y DRIVE Assy
IC5V D/D CONV. BLOCK
Y DRIVE Assy
RESET BLOCK
DIGITAL VIDEO Assy
IC751 • 752 • 755
SCAN IC
IC851 • 852 • 853
IC801 • 803
IC801 • 802 • 803
R3717 • 3730
IC851 • 853
Pulse module
IC3604 • 3605 • 3609 • 3610
IC3611 • 3612 • 3613 • 3615 • 3601
• 3602 • 3603 • 3614
Q3708
IC2201 (IC23)
D407
•
D439
D407
•
D437
The state of
circuit
P.D. circuit
in operation
Diagnosis
Failure points
Estimated failure parts
Lighting
LED
OVP: Over Voltage Protection, OCP: Over Current Protection, UVP: Under Voltage Protection
Diagnosis of malfunctions by power coming up sequence
Vsus 170V
Vadr 59V
Vcc
+14V/+8V/+12V/VF
STBY +5V/+12V
Approx.
1.3 sec
Approx. 1.4 sec (AC100V)
Approx. 0.04 sec (AC220V)
Approx.
0.4 sec
0.02 sec
or more
Vsus discharge
Vadr
STBY LED
ON (RED)
D205 (RED)
D355 (RED)
ON
D305 (RED)
ON
D205 (YEL)
ON
Main Power
off
Power
off
Power
off
Main
Power
on
Power
on
STBY
mode
STBY
mode
Power
off
The power coming up sequence of power supply
Simple diagnosis using LEDs at Main Power Assy
The state of LEDs at Main Power Assy
Estimated P.D. circuit in operation
After D205 lights up in red, D407 lights up. (D205 lights up in yellow in normal operation.)
VSUS UVP
After D305 is put out the light, D407 lights up. (D305 lights up in red in normal operation.)
VADR UVP
After D355 is put out the light, D407 lights up. (D355 lights up in red in normal operation.)
14V • 12V • ±8V UVP, B OVP, VF OVP
D407 lights up at the stand-by mode.
AC200V P.D.
After D205, D305 and D355 lights up normally, D407 lights up.
VSUS OVP
After D305 and D355 lights up normally, D407 lights up.
VADR OVP
After D355 lights up normally, D407 lights up.
14V OVP
Summary of Contents for PDP-505HD
Page 5: ...PDP 505HD 5 ...
Page 45: ...PDP 505HD 45 ...
Page 46: ...PDP 505HD 46 A B C D 1 2 3 4 1 2 3 4 3 11 OVERALL CONNECTION DIAGRAM 1 2 ADX2643 ...
Page 47: ...PDP 505HD 47 A B C D 5 6 7 8 5 6 7 8 ADX2643 ADX2643 ADX2643 ADX2643 ADX2643 ...
Page 49: ...PDP 505HD 49 A B C D 5 6 7 8 5 6 7 8 ADX2643 ADX2643 ADX2643 ADX2643 ...
Page 51: ...PDP 505HD 51 A B C D 5 6 7 8 5 6 7 8 AUTO ZOOM BLOCK ...