PDP-436SXE
96
1
2
3
4
1
2
3
4
C
D
F
A
B
E
Data Arrangement
Data
Length
Output Example
ECO
3Byte
QSD
1
Latest SD data
1byte
1
2
Latest SD subcategory data
1byte
0
3
Data from the hour meter for the latest SD
8byte
00752013
4
Second latest SD data
1byte
5
5
Second latest SD subcategory data
1byte
0
6
Data from the hour meter for the second latest SD
8byte
00495204
7
Third latest SD data
1byte
2
8
Third latest SD subcategory data
1byte
3
9
Data from the hour meter for the third latest SD
8byte
00100355
10
Fourth latest SD data
1byte
2
11
Fourth latest SD subcategory data
1byte
5
12
Data from the hour meter for the fourth latest SD
8byte
00075620
13
Fifth latest SD data
1byte
1
14
Fifth latest SD subcategory data
1byte
0
15
Data from the hour meter for the fifth latest SD
8byte
00000852
16
Sixth latest SD data
1byte
2
17
Sixth latest SD subcategory data
1byte
5
18
Data from the hour meter for the sixth latest SD
8byte
000000451
19
Seventh latest SD data
1byte
0
20
Seventh latest SD subcategory data
1byte
0
21
Data from the hour meter for the seventh latest SD
8byte
00000000
22
Eighth latest SD data
1byte
0
23
Eighth latest SD subcategory data
1byte
0
24
Data from the hour meter for the eighth latest SD
8byte
00000000
CS
2Byte
7D
Command
Format
Effective Operation
Modes
Function
Remarks
[QSD]
All operations
To acquire data on the shutdown logs
Return data: 3 (ECO)+80(DATA)+2(CS)=85Byte
7
Acquisition of SD logs • • • [QSD]
The command QSD is for acquiring the data from the 8 latest shutdown (SD) logs.
¶
SD data
0
No SD
1
SQ-IC
2
MDU-IIC
3
RST2
4
Panel having high temperature
5
Short-circuited speaker
¶
SD subcategory
0
No SD subcategory
1
EEPROM
2
BACKUP
3
DAC
4
VOL-IC
5
DVI
6
Not used