PDP-LX5080D
85
5
6
7
8
5
6
7
8
C
D
F
A
B
E
6.1.6 FACTORY HIERARCHICAL TABLE
Large Item
Variable / Adjustment Range
Remarks
Middle Item
Small Item
6.2.1 INFORMATION
6.2.1.1
V
ERSIO
N
(1)
6.2.1.2
V
ERSIO
N
(2)
CLEAR <=>
N
O <=> YES
6.2.1.3 MAI
N
N
G
6.2.1.4 TEMPERATURE
6.2.1.5 HOUR METER
6.2.1.6 HDMI SIG
N
AL I
N
FO 1
6.2.1.7 HDMI SIG
N
AL I
N
FO 2
6.2.1.9
V
DEC SIG
N
AL I
N
FO 2
6.2.1.
8
V
DEC SIG
N
AL I
N
FO 1
6.2.2 PANEL FACTORY (+)
6.2.2.1 PA
N
EL I
N
FORMATIO
N
6.2.2.2 PA
N
EL
W
ORKS
6.2.2.3 PO
W
ER DO
WN
6.2.2.4 SHUT DO
WN
6.2.2.5 PA
N
EL-1 ADJ (+)
V
OL SUS <=>
000 to 255
Equivalent to
V
SU (Setting value: Factory adjustment value)
V
OL OFFSET <=>
000 to 255
Equivalent to
V
OF (Setting value: Factory adjustment value)
V
OL RST P <=>
000 to 255
Equivalent to
V
RP (Setting value: Factory adjustment value)
V
OL XPOFS1 <=>
000 to 255
Equivalent to
V
X1 (Setting value: Factory adjustment value)
V
OL XPOFS2 <=>
000 to 255
Equivalent to
V
X2 (Setting value: Factory adjustment value)
V
OL Y
N
OFS1 <=>
000 to 255
Equivalent to
V
Y1 (Setting value: Factory adjustment value)
V
OL Y
N
OFS3 <=>
000 to 255
Equivalent to
V
Y3 (Setting value: Factory adjustment value)
V
OL Y
N
OFS4 <=>
000 to 255
Equivalent to
V
Y4 (Setting value: Factory adjustment value)
RESET1ST_KSB <=>
112 to 144
Equivalent to R1K (Setting value: 12
8
fixed)
RESET2
N
D_KSB <=>
112 to 144
Equivalent to R2K (Setting value: 12
8
fixed)
YSTL_1SF_KSB <=>
112 to 144
Equivalent to Y1K (Setting value: 12
8
fixed)
YSTL_1SF_HZ <=>
112 to 144
Equivalent to Y1Z (Setting value: 12
8
fixed)
XSUS_1ST_B <=>
112 to 144
Equivalent to X1B (Setting value: 12
8
fixed)
YSUS_2
N
D_B <=>
112 to 144
Equivalent to Y2B (Setting value: 12
8
fixed)
XSUS_3RD_B <=>
112 to 144
Equivalent to X3B (Setting value: 12
8
fixed)
YSUS_B <=>
112 to 144
Equivalent to YSB (Setting value: 12
8
fixed)
XSUS_B <=>
112 to 144
Equivalent to XSB (Setting value: 12
8
fixed)
YSTL_KSB <=>
112 to 144
Equivalent to YTK (Setting value: 12
8
fixed)
YSTL_HZ <=>
112 to 144
Equivalent to YTZ (Setting value: 12
8
fixed)
YSTL_2SF_KSB <=>
112 to 144
Equivalent to Y2K (Setting value: 12
8
fixed)
YSTL_2SF_HZ <=>
112 to 144
Equivalent to Y2Z (Setting value: 12
8
fixed)
YSTL_FMR_KSB <=>
112 to 144
Equivalent to Y
N
K (Setting value: 12
8
fixed)
YSTL_FMR_HZ <=>
112 to 144
Equivalent to Y
N
Z (Setting value: 12
8
fixed)
SUS FREQ. <=>
MODE 1 to MODE
8
Equivalent to SFR (Setting value: MODE1)
6.2.2.6 PA
N
EL-2 ADJ (+)
R-HIGH <=>
000 to 511
Equivalent to PRH (Setting value: Factory adjustment value)
G-HIGH <=>
000 to 511
Equivalent to PGH (Setting value: Factory adjustment value)
B-HIGH <=>
000 to 511
Equivalent to PBH (Setting value: Factory adjustment value)
R-LO
W
<=>
000 to 999
Equivalent to PRL (Setting value: 512 fixed)
G-LO
W
<=>
000 to 999
Equivalent to PGL (Setting value: 512 fixed)
B-LO
W
<=>
000 to 999
Equivalent to PBL (Setting value: 512 fixed)
ABL <=>
000 to 255
Equivalent to ABL (Setting value: Factory adjustment value)
6.2.2.7 PA
N
EL FU
N
CTIO
N
(+)
R-LE
V
EL <=>
L
V
-0 to L
V
-7
Equivalent to RRL (Setting value: Lv-1)
G-LE
V
EL <=>
L
V
-0 to L
V
-7
Equivalent to RGL (Setting value: Lv-1)
B-LE
V
EL <=>
L
V
-0 to L
V
-7
Equivalent to RBL (Setting value: Lv-0)
ADDRESS L1 <=>
PH0 to PH9
Equivalent to AP0S*- (Setting value: PH2)
ADDRESS L2 <=>
PH0 to PH9
Equivalent to AP0S-* (Setting value: PH1)
ADDRESS L3 <=>
PH0 to PH9
Equivalent to AP1S*- (Setting value: PH1)
ADDRESS L4 <=>
PH0 to PH9
Equivalent to AP1S-* (Setting value: PH2)
ADDRESS U1 <=>
PH0 to PH9
Equivalent to AP2S*- (Setting value: PH2)
ADDRESS U2 <=>
PH0 to PH9
Equivalent to AP2S-* (Setting value: PH1)
ADDRESS U3 <=>
PH0 to PH9
Equivalent to AP3S*- (Setting value: PH1)
ADDRESS U4 <=>
PH0 to PH9
Equivalent to AP3S-* (Setting value: PH2)
STK MODE <=>
OFF <=> MODE1 to MODE
8
<=>
Equivalent to SMK (Setting value: MODE1)
6.2.2.
8
ETC. (+)
BACKUP DATA <=>
N
O OPRT <=> TRA
N
SFER or ERR
Equivalent to BCP
DIGITAL EEPROM <=>
N
O OPRT <=> DELETE/REPAIR
Equivalent to FAJ/UAJ
PD I
N
FO. <=>
N
O OPRT <=> CLEAR
Equivalent to CPD
SD I
N
FO. <=>
N
O OPRT <=> CLEAR
Equivalent to CSD
HR-MTR I
N
FO. <=>
N
O OPRT <=> CLEAR
Equivalent to CHM
PM/B1-B5 <=>
N
O OPRT <=> CLEAR
Equivalent to CPM
P COU
N
T I
N
FO. <=>
N
O OPRT <=> CLEAR
Equivalent to CPC
MAX TEMP. <=>
N
O OPRT <=> CLEAR
Equivalent to CMT
6.2.2.9 RASTER MASK SETUP (+)
MASK OFF
Equivalent to MKS+S00
RST MASK 01 <=>
<=> 4
8V
<=> 50
V
<=> 60
V
<=>
60P <=> 72
V
<=> 75
V
<=>
Equivalent to MKS+S51
• • •
• • •
RST MASK 25 <=>
Equivalent to MKS+S75
*: Setting value
Summary of Contents for KURO PDP-LX508D
Page 19: ...PDP LX5080D 19 5 6 7 8 5 6 7 8 C D F A B E ...
Page 20: ...PDP LX5080D 20 1 2 3 4 1 2 3 4 C D F A B E 4 BLOCK DIAGRAM 4 1 OVERALL WIRING DIAGRAM 1 2 ...
Page 22: ...PDP LX5080D 22 1 2 3 4 1 2 3 4 C D F A B E 4 2 OVERALL WIRING DIAGRAM 2 2 ...
Page 23: ...PDP LX5080D 23 5 6 7 8 5 6 7 8 C D F A B E ...
Page 159: ...PDP LX5080D 159 5 6 7 8 5 6 7 8 C D F A B E ...
Page 170: ...PDP LX5080D 170 1 2 3 4 1 2 3 4 C D F A B E 10 6 PANEL CHASSIS SECTION ...