6
46
Others
This section shows the communication examples of RS-232C.
Operating command
RS-232C Communication Examples
Type
Command
Description
Connection check
PC
This unit: 21 89 01 00 00 0A
This unit
PC: 06 89 01 00 00 0A
Checks connection
Power (On)
PC
This unit: 21 89 01 50 57 31 0A
This unit
PC: 06 89 01 50 57 0A
When power is turned on from standby mode
Power (Off)
PC
This unit: 21 89 01 50 57 30 0A
This unit
PC: 06 89 01 50 57 0A
When power is turned off (standby mode)
from power-on mode
Input (COMP.)
PC
This unit: 21 89 01 49 50 32 0A
This unit
PC: 06 89 01 49 50 0A
When video input is set to component
Remote Control
(MENU)
PC
This unit: 21 89 01 52 43 37 33 32 45 0A
This unit
PC: 06 89 01 52 43 0A
When the same operation as pressing the
[MENU] button on the remote control is made
Gamma table
(User)
PC
This unit: 21 89 01 47 54 34 0A
This unit
PC: 06 89 01 47 54 0A
When switched to “User”
Gamma coefficient
(1.8)
PC
This unit: 21 89 01 47 50 30 0A
This unit
PC: 06 89 01 47 50 0A
When set to “1.8”
Gamma data
(R)
PC
This unit: 21 89 01 47 52 0A
This unit
PC: 06 89 01 47 52 0A
PC
This unit: 512 bytes of gamma data
This unit
PC: 06 89 01 47 52 0A
When the red gamma data is set
Test pattern
(Staircase)
PC
This unit: 21 89 01 54 53 36 0A
This unit
PC: 06 89 01 54 53 0A
When staircase (gray) is set
KRF-9000FDE_EN.book Page 46 Tuesday, February 19, 2008 9:16 AM
Summary of Contents for KURO KRF-9000FD
Page 5: ...5 Getting Started Preparation Basic Operation Settings Troubleshooting Others ENGLISH ...
Page 52: ...6 52 Others Memo ...
Page 57: ...5 Pour commencer Préparation Fonctionnement Réglages Dépannage Autres FRANÇAIS ...
Page 104: ...6 52 Autres Memo ...
Page 156: ...6 52 Otros Memo ...
Page 208: ...6 52 Andere Memo ...