Service Valve Operation Instructions

1.          Opening the Service Valves

1.

2.

3.

Remove  the  cap  and  turn  the  valve  counter- 
clock-wise  with  the  hexagonal  wrench.

Turn until the shaft stops. Do not apply excessive force 
to the service valve. Doing so may break the valve 
body, as the valve is not of the backseat type. Always 
use the special tool.

Make sure to tighten the brass cap securely.

Make sure to tighten the brass cap securely.

2.          Closing the Service Valves

1.

2.

Remove the cap, and turn the valve clockwise with the 
hexagonal wrench.

Securely tighten the valve until the shaft contacts the 
main body seal.

Flare Nut

Hexagonal
Dust Cap

Valve Core

11.  

Remove the charging hose from the service port.

12.

 

Using a hexagonal wrench, fully open both the 
LIQUID side and GAS side service valves.

13.  

Tighten valve caps on all three valves (Service 
Port, Liquid Side, Gas Side) by hand. 
Then ,  tighten it further using a torque 
wrench, if needed.

 OPEN VALVE STEMS GENTLY

 

When opening valve stems, turn the hexagonal 
wrench until it seats against the stopper. Do not 
try to force the valve to open further.

Fig. 6.2

Copper Pipe from Indoor Unit

   Service Port
(Only the GAS Side
Valve has this port)

CAUTION

The drain pipe of the indoor unit must be heat-insulated, or it,as 
well as the connections of the indoor unit, will condense dew.

Hard PVC binder must be used for the pipe connection. Make 
sure there is no leakage.

With the connection part to the indoor unit, please ensure not to 
apply pressure on the side of indoor unit pipes.

When the declivity of the drain pipe downwards is over 1/100, 
there should not be any winding.

The total length of the drain pipe, when pulled out transversely, 
shall not exceed 20m. When the pipe is overlong, a prop stand 
must be installed to prevent winding. 

Refer to the figures below for the installation of the pipes. 

8.    CONNECT THE DRAIN PIPE

Install the Drainpipe of the Indoor Unit

The outlet has a PTI screw thread.Please use sealing materials 
and pipe sheath (fittings) when connecting PVC pipes. 

Drainage Test

Check whether the drainpipe is unhindered.

Newly-built  houses  should  have  this  test  done  before 
paving the ceiling.

1.5m~2m

Insulating

material

Downward declivity

lower than 1/100 

Bend

S shape 

VP30

Downward declivity 

lower than 1/100

Put as deep as possible

(about 10cm)

Fig. 8-1

Install the Drain Joint of the Outdoor Unit

Fit the seal into the drain joint, then insert the drain joint into the 
base  pan  hole  of  outdoor  unit,  rotate  90  to  securely  assemble 
them.  Connect  the  drain  joint  with  an  extension  drain  hose 
(locally  purchased),  in  case  of  condensate  draining  off  the 
outdoor unit during heating mode. 

(Refer to Fig. 8-2)

Summary of Contents for FAB Series

Page 1: ...his manual carefully before installing or operating your new air conditioning system Make sure to save this manual for future reference Installation Manual FAB FYB Series FAB Cooling Only Version FYB Cooling and Heating Version Inverter and Inverter Models 9 000 BTU h through 12 000 BTU h ...

Page 2: ...If used as a part of a MULTI Split System please refer to the Installation Operation manuals packed with the multi split outdoor unit ...

Page 3: ...nsufficient or the installation is improperly done the set can possibly drop and cause injury The appliance shall not be installed in or near the laundry room Before obtaining access to the terminals all supply circuits must be disconnected The appliance must be positioned so that the plug is easily accessible The enclosure of the appliance shall be marked by words or by symbols with the direction...

Page 4: ...ended for use by young children or infirm persons without supervision Don t install the air conditioner in the following locations Anywhere that contains unsealed petrolatum Areas with salt saturated air such as near the coast Areas with caustic gas sulfide for example existent in the air such as near a hot spring Areas with fluctuations in incoming power supply or unstable power where the voltage...

Page 5: ...sitive and negative poles are in their proper positions when loading batteries This manual is subject to changes due to technological improvement without further notices Cautions regarding Remote Controller installation Remote Controller Remote Controller Holder Mounting Screw B ST2 9x10 C H Table 3 1 QUANTITY SHAPE NAME 1 Hook 6 Owner s Manual 7 Installation Manual 2 Remote Controller 3 Frame 5 A...

Page 6: ...ent image interference and noise coming from those electrical appliances Noise may be generated depending on the conditions under which the electric wave is generated even if a 1 meter distance is kept There is sufficient room for installation and maintenance Refer to Fig 5 1 and Fig 5 2 The outlet and the inlet are not impeded and the influence of external air is minimized The air flow has reach ...

Page 7: ...he drain hole and drained away to an appropriate place so as not to affect other nearby people Select the best position that will not be subject to snow drifts accumulation of leaves or other seasonal debris If unavoidable please cover the unit with a shelter Install the unit in a location that is as close as possible to the indoor unit If possible remove all nearby obstacles so as to prevent air ...

Page 8: ...installation Connecting pipes should not be installed until the indoor and outdoor units have already been fixed into place Keep the connecting pipes dry and do not let moisture inside during installation Heat insulation work should be installed properly and fully on both sides of the gas piping and the liquid piping Otherwise there can be a risk of water leakage Pipe Connection Procedure 7 1 Tabl...

Page 9: ... Refer to Fig 7 3 Fig 7 2 Fig 7 3 How to take outdoor unit apart to connect the pipes Remove the water tray Refer to Fig 7 4 Remove the water tray Refer to Fig 7 4 Flaring 1 Cut pipe using a pipe cutter Refer to Fig 7 5 Insert a flare nut into the pipe then flare the pipe Refer to Table 7 2 for the dimension of flare nut spacings 90 Lean crude burr Fig 7 5 Fig 7 4 How to Connect the Pipes Water Tr...

Page 10: ... 32 Ø 3 8 Ø 1 2 Ø 5 8 Hexagonal wrench 6 mm Ø 3 4 Hexagonal wrench 10 mm Ø 1 Service Port Cap 26 32 17 20 13 16 4 5 6 7 5 10 12 20 25 8 5 10 2 10 12 MC MC BLUE Low Pressure Side of Manifold Gauge RED High Pressure Side of Manifold Gauge YELLOW Common Side of Manifold Gauge BLUE Low Pressure Gauge RED High Pressure Gauge Low Pressure Valve High Pressure Valve Preparations and Precautions can cause ...

Page 11: ...Valve Fig 6 2 9 Insert hexagonal wrench into the service valve LIQUID Side Valve and open the valve by turning the wrench in a 1 4 counterclockwise turn Listen for the sound of gas exiting the system then close the valve after 5 seconds 10 Watch the Pressure Gauge for a few minutes to make sure that there is no drop in the pressure value indicating a leak The Low Pressure Gauge should now show a p...

Page 12: ... must be heat insulated or it as well as the connections of the indoor unit will condense dew Hard PVC binder must be used for the pipe connection Make sure there is no leakage With the connection part to the indoor unit please ensure not to apply pressure on the side of indoor unit pipes When the declivity of the drain pipe downwards is over 1 100 there should not be any winding The total length ...

Page 13: ...ly The power connection for the air conditioner has to be done at the main power distribution source The distribution has to be of a low impedance normally the required impedance is reached at a 32A fusing point No other equipment should be connected with this power line For detailed installation exceptions please refer to your power supplier to confirm if restrictions apply for products like wash...

Page 14: ...nnected correctly The length of the tubing and the added stow capacity of the refrigerant have been recorded The power voltage fits the rated voltage of the air conditioner There is no obstacle at the outlet and inlet of the outdoor and indoor units The gas side and liquid side stop valves are both open The air conditioner is pre heated by turning on the power Set the air conditioner to COOLING mo...

Page 15: ...8 000 BTU hr OUTDOOR UNIT POWER WIRING STRONG ELECTRIC SIGNAL WEAK ELECTRIC SIGNAL Wiring Figure The power supply included in the above mentioned can be applied to the table Before obtaining access to terminals all supply circuits must be disconnected CAUTION Fig 9 4 Ground Wiring Ground Wiring Power Supply Switch Fuse Available locally Power Wiring Indoor Power Linking Wiring Outdoor Strong elect...

Page 16: ...Unit Ground the air conditioner properly to ensure its anti interference function Fig 10 6 Ground Wiring Ground Wiring Power Supply Switch Fuse Available locally Power Wiring indoor Power linking Wiring Outdoor Weak electric signal link wiring Indoor Unit Outdoor Unit Power Supply Ground the air conditioner properly to ensure its anti interference function Magnetic Ring optional Hitch onto the com...

Page 17: ...nding chart or it may lead to damage The signs of the indoor terminal block in some of following fugures may be replaced by L N L1 N1 CAUTION Fig 9 7 Ground Wiring Ground Wiring Power Supply Switch Fuse Available locally Power Wiring Outdoor Strong electric signal link wiring Weak electric signal link wiring Indoor Unit Outdoor Unit Ground the air conditioner properly to ensure its anti interferen...

Page 18: ...with the sales agency for manufa cturer for details is a registered trademark of Parker Davis HVAC International Inc Parker Davis HVAC International Inc 2250 NW 102 Place Doral FL 33172 USA Tel 305 513 4488 Fax 305 513 4499 email info pd hvac com Website www pd hvac com Copyright 2017 Parker Davis HVAC International Inc All rights reserved ...

Page 19: ......

Reviews: