Techno Tidbits and Problem-solving
103
EX
P
E
RT
During playback of a 96kHz
source, the display doesn't
show 96kHz
• SIGNAL SELECT is set to ANALOG
• SET the SIGNAL SELECT to AUTO (see
page 44).
Cannot be remote controlled.
• The remote control batteries have worn
out.
• Too far away or improper angle of opera-
tion.
• There is an obstacle between the
receiver and the remote control.
• Strong light such as fluorescent light is
shining onto the unit's remote control
signal light-receiving window.
• A cord is connected to the CONTROL IN
terminal on this unit.
• The IR Receiver type is mismatched with
the setting.
• Replace the batteries (see page 7).
• Operate within 23 feet and a 30° angle
of the remote sensor on the front panel
(see page 8).
• Remove the obstacle or operate from
another position (see page 8).
• Avoid exposing the remote sensor on
the front panel to direct light.
• Connect cord to the correct jack.
• Disconnect the IR Receiver from the
rear panel, and set to the other IR
Receiver type using the remote control.
Other components can't be
operated with the system
remote.
• The preset code settings are wrong.
• The batteries wore out and the system
settings were cleared.
• Input the correct preset code.
• Reset the proper system settings.
The SR cable is connected, but
the connected components
can't be operated with the
remote.
• The SR cable hasn't been connected
properly.
• The rest of the component connection
have not been made.
• The component you have hooked up is
not SR compatible.
• Reinsert the SR cable, making sure it is
the right jack (see page 74).
• Make sure an analog connection has
been made between the units.
• This is not a malfunction.
There seems to be a time lag
between the speakers and the
output of the subwoofer.
• The subwoofer channel can be delayed
slightly if run through a low-pass filter.
• The MCACC system will automatically
compensate for a delay in the sub-
woofer output during the Auto Sur-
round Sound Setup.
Miscellaneous
Cause
Remedy
Remote control
If the unit does not operate normally due to external effects such as static electricity
Disconnect the power plug from the outlet and insert again to return to normal operating conditions.
Symptom