S-W1EX
39
5
6
7
8
5
6
7
8
C
D
F
A
B
E
6. ADJUSTMENT
1
3
4
2
FRONT SIDE
CN481
L481
DC OFFSET CHECK POINT
D AMP ASSY
VR32
ADJ OUTPUT DC OFFSET
1. Touch the instrument probe to naked terminal or land (V1, V2) as picture
1
,
2
,
3
.
2. Turn on the unit and wait about 1 minute.
3. Rotate VR321 and adjust to DC 0 V
±
20mV.
PROCEDURE
V2
V1
SP-
SP+
When necessary
to confirm
How to confirm
Setting of the model
AC rating power supply
Power : ON
Input signal : No signal
Main Volume : minimum
Speaker is connected to CN481.
(Or 4
Ω
dummy load/ open)
1. When exchanging MOS FET Q421, Q431, Q441, Q451 (IRFB23N15D)
2. When exchanging IC421, IC441 (IR2011S)
3. When exchanging D AMP ASSY (AWU8170)
D AMP ASSY (AWU8170)
E