DVD-V5000 DVD Player
RS-232 Command Protocol
3.4 Error
Messages
If an error occurs during a command execution, the player returns an error code.
The table below lists each code with a description of the error:
Code Message
Description
E00 Communication
error
Communication Line Error due to framing error
or buffer overflow
E04
Feature not available
Non-Usable Function has been tried – either
the command mnemonic is wrong or the
command can not be used in this mode
E06 Missing
argument
Correct parameter is not specified
E11
Disc does not exist
There is no disc in the tray
E12 Search
error
Search address is missing
E15 Picture
stop
Playback has been stopped by VOBU Still while
in the Auto Play mode
E16
Interrupt by other device
The command(s) sent via the serial line were
not executed before commands were sent from
the front panel buttons and/or remote control
E99 Panic
Unrecoverable Error occurred – possible that a
disc cannot be loaded and/or playing does not
continue
3.5 Initial
Setting
The following table provides the default internal register and switch settings.
Take care when setting the required parameters for an application program.
Register/Switch
Setting at Power ON
Video Switch
1 : ON
Audio Switch
3 : Audio 1
Display Switch
0 : OFF
Address mode
1 : Time
Speed Parameter
15 : 1/4 Speed
CCR 3
:
Mode
3
Register A
3 : Title/Chapter and Frame
Display (DVD)
Track/Time Display (CD, VCD)
Register D
0 : CR
- 8