Appendix A
Troubleshooting IBM- PC DOS / WINDOWS Installation
Owner’s Manual / Software Driver Installation Guide
A-11
BUSY light Flashes
at one-second
intervals
1.
This is a visual indicator from the drive that something is
wrong with the drive, affecting its ability to perform.
It may be a
mechanical problem. Or, the drive may be in test mode.
2.
Make sure the switch for Test Mode is DOWN/OFF.
Refer to
Operating Instructions
. For almost all DOS applications, only the
terminator switch on the DRM-602X should be up. All others on the
DRM602X and all switches on the DRM604X should be down.
1.
It you are not booting from a SCSI hard drive using this SCSI
interface card card, and if there is a boot ROM on the interface
card, the boot ROM should be removed or disabled using software
options.
2.
If booting from a SCSI Hard drive, make sure the SCSI IDs do
not conflict and that termination on the SCSI interface card is
disabled.
Consult documentation for interface card manufacturer.
NOTE: The hard drive should be terminated as the first device on the
chain and if the the Pioneer Changer is the only other device on the line,
it should also be terminated.
Boot problems or the
unit only accesses
Drive D
3.
Verify that the Pioneer Changer is functioning properly.
Refer to
TB #168
to run a Self-Test on the unit and to
TB #169
to run an Audio
Play test. These documents are available as
32 169
&
32 170
on the
Pioneer LaserFacts System;
see
Appendix F.