2.2 Figure
of
B
ody
S
ize
2.
OUTDOOR
UNIT
INSTALLATION
2.1
Precautions
for
Location Selection
1)
Choose
a
place
sturdy
enough
to
bear
the
weight
and
vibration
s
of
the
unit,
and
where
the
operation
noise
will
not
be
amplified.
2)
Choose
a
location
where
neither
the
hot
air
discharged
from
the
unit
n
or the
operation
noise
will
cause
a
nuisance
to
the
neighbors of
the
user.
3)
Avoid
places
near
bedroom
s
and
the
like,
so
that
the
operation
noise
will
cause
no
disturbances.
4)
There
must
be
sufficient
space
for
carrying
the
unit
into
and
out
from
the
site.
5)
There
must
be
sufficient
space
for
air
passage,
and
no
obstructions
around
the
air
inlet
and
the
air
outlet.
6)
The
site
must
be
free
from
the
poss心lity
of
flammable
gas
leakage
in
a
nearby
place.
7)
Install
units,
power
cords,
and
inter-unit
wire
at
least
3m
away
from television
and
radio
sets.
This
is
to
prevent
interference
from
images
and
sounds.
(Noises
may
be
heard
even
if
they
are
more
than
3m
away,
depending
on
radio
wave
cond仆ions.)
8)
In
coastal
areas,
or
other
places
with
salty
atmosphere,
o
r
sulfate
gas,
corrosion
may
shorten
the
life
of
the
air
conditioner.
9)
Since
drain
flows
out
of
the
outdoor
unit,
do
not
place
anything
underneath the
unit that
must
be
kept
away
from
moisture
NOTE:
Cannot
be
installed
hanging
from
ceiling,
or
stacked.
A
CAUTION
When
operating
the
air
conditioner
in
a
low
outdoor
ambient
temperature,
be
sure
to
follow
the
instructions described
below.
-
To
prevent
exposure
to
wind,
install
the
outdoor
unit
with
its
suction
side
facing
the
wall.
-
Never
install
the
outdoor
unit
in
a
site
where
the
suction
side
may
be
exposed
directly
to
wind.
-
To
prevent
exposure
to
wind,
it
is
recommended
to
install
a
baffle
plate
on
the
air
discharge
side
of
the
outdoor
unit.
-
In
heavy
snowfall
areas,
select
an
installation
site
where
the
snow
will
not
affect
the
unit.
工
A
B
-
ID一
LL
,
-
J
山1010
Unit:mm
MODEL
A
B
C
E
D
H
F
780
548
266
300
241
250
540
9K-18K 760
530
290
315
270
285
590
810
549
325
350
305
310
558
845
560
335
360
312
320
700
(in
=
mm/25.4)
1)
Caution
on
pipe
handling
•
Protect
the
open
end
of
the
pipe
against
dust
and
moisture.
•
All
pipe
bends
should
be
as
gentle
as
possible.
Use
a
pipe
bender
for
bending.
- Construct a la「ge canopy.
- Construct a pedestal.
Install the unit high enough off the
ground to prevent burying in snow
Rain
11'I'
''ii:
I I 1
If no flare cap is
available, cover the
flare mouth with
tape to keep dirt or
water out.
归
7