RF
AGND2
Oscilloscope
The skew adjustment for the pickup is required when the following replacement is performed:
(1) Replacement of the pickup unit
(2) Replacement of the spindle motor
(3) Replacement of the carriage chassis
(4) Replacement of the main shaft of the pickup unit
(5) Replacement of the sub-shaft of the pickup unit
Measuring instrument, jigs and tools: Oscilloscope
Driver for adjusting SKEW => torques (T2) driver
Bond for fixing SKEW (GEM1033)
Bond for screw lock (GEM1068)
Disc used: GGV1025
Measurement criterion: AGND2
Measurement point: RF
Connection diagram
DVD core unit
-
SKEW adjustment
Symptoms seen in case of inadequate adjustment: Worsened error ratio 10-3 (normally 10-4 or less)
Large RF jitter
RF waveform is distorted
Tracking leading-in/servo is unstable
* Note: Do not directly look at laser beam in adjustment.
There are two types of adjustments available: adjustment while monitoring the RF waveform with the oscilloscope
(method
1
) and adjustment while checking the RF level values with the OSD (method
2
).
The adjustment procedure is shown below. For how to enter the test mode and the operation procedure, see the
sections in the Service Test Mode.
Summary of Contents for AVH-X7700BT/XNEW5
Page 81: ...AVH X7700BT XNUC 81 5 6 7 8 5 6 7 8 C D F A B E ...
Page 85: ...AVH X7700BT XNUC 85 5 6 7 8 5 6 7 8 C D F A B E ...
Page 105: ...AVH X7700BT XNUC 105 5 6 7 8 5 6 7 8 C D F A B E ...
Page 117: ...AVH X7700BT XNUC 117 5 6 7 8 5 6 7 8 C D F A B E ...
Page 123: ...AVH X7700BT XNUC 123 5 6 7 8 5 6 7 8 C D F A B E ...
Page 143: ...AVH X7700BT XNUC 143 5 6 7 8 5 6 7 8 C D F A B E ...