(4) In 600 ms, the motor for backward and forward drive is stopped and the motor for angle drive is rotated in UP direction.
(5) If the angle VOL voltage becomes approximately 90° voltage, the motor for angle drive is braked and the ejection is
completed. (If the previous angle is memorized, the system operates at the angle)
90° voltage or last memory position
(6) If the setback setting is turned ON, the motor for angle drive is braked after the monitor angle voltage reaches the
previous angle memory, and then the motor for backward and forward drive is rotated in the storage direction at low
speed. After that, if the status of analog signal of O/C/D SW changes from 4 to 5, the motor for backward and forward
drive is stopped.
(7) To remove the backlash of gear, the motor for backward and forward drive is rotated in horizontal ejection direction for
32ms, and then it is stopped.