72
AVD-W6000
VDD=5V
Pin 68
Power ON
L
H
POWER key
ON
OVICHK
Pin 56
MVICHK
Pin 80
MVIPW
←
H
Pin 41
POWER key valid
MFLPW
←
H
Pin 42
If the MPLPW signal does not rise to
"MPLPW = H" when the POWER key is turned on,
there is a possibility of occurrence of
"OVICHK = L" or "MVICHK
≤
3.5[V]".
≤
3.5[V]
>3.5[V]
Completes power-on operation.
-
Monitor Unit