Pintek PW-3063R Instruction Manual Download Page 5

3. Use only a 3-wire outlet, and do not attempt to defeat the ground terminal on the power 

plug to fit into 2-wire outlet. The chassis and housing of the instrument are grounding  
through this terminal and it could cause safety hazard if the ground terminal is not well 
connected.

4. Do not obstruct the ventilation holes at the rear panel. As this will increase the internal 

temperature.

5. Never apply external voltage to the output terminal of this instrument.
6. The instrument is designed for 

INDOOR USE ONLY

.

7. This instrument has been evaluated to 

INSTALLATION CATEGORY II, 

POLLUTION DEGREE 2

.

8. A certified power supply cord and AC inlet has to be used with this equipment. The 

applicance coupler is the disconnect device to disconnect the main power. 

DO NOT 

remove the equipment before disconnect the appliance coupler.  

9. The power cord set shall have a power supply cord with conductors providing a wire 

gauge of No.18 AWM minimum. The minimum electrical ratings shall be 125 V~, 60Hz, 
15A and marked SJT or SVT etc.

DC POWER SUPPLY

Maintenance

GENERAL MAINTENANCE:

1. Preventive maintenance --- Clean and re-calibrate the instrument on a regular basis to 

keep the instrument looking nice and working will.

2. Cleaning --- Remove any dirt, dust and grime whenever they become noticeable on the 

outside cover with a soft cloth moistened with a mild cleaning solution.

3. Servicing --- if the instrument ever becomes inoperative or damaged, refer servicing to a 

qualified repair facility.

FUSE REPLACEMENT:

If the fuse blows, the LED will not light and the instrument will not operate.  Replace 
only with the fuse specified in this manual.  The fuse is located on the rear panel adjacent 
to the power cord receptacle. Remove the fuse holder assembly as follows:

1. Unplug the power cord from rear of the instrument.
2. Insert a small screwdriver in fuse holder slot (located between fuse holder and receptacle). 

Pry fuse holder away from receptacle.

3. When reinstalling fuse holder, be sure that the fuse is installed so that the correct line 

voltage is selected.

2

Summary of Contents for PW-3063R

Page 1: ...Model PW 3063R PW 4063R INSTRUCTION MANUAL DC POWER SUPPLY ...

Page 2: ......

Page 3: ...ion Description Operation Instruction A Setting the output voltage and output current B Operation Modes of 3063R C Operation Modes of 4063R D of 3063R 4063R 1 Symbol Description 2 Front Panel 3 Rear Panel Description Front Panel Table of Contents 1 2 3 4 4 6 9 7 7 7 4 11 ...

Page 4: ...sure to check the set up with line voltage 1 Selector Line Voltage Fuse 115V 230V 100 125V 50 60Hz 220 240V 50 60Hz PW 3063R PW 4063R T10A T6A T10A T6A Hints for operation 1 Do not place heavy objects on this instrument 2 Do not place a hot soldering iron on or near this instrument 3 Never insert wires pins or other metal object into ventilation fan 4 Never move or pull the instrument with power c...

Page 5: ...No 18 AWM minimum The minimum electrical ratings shall be 125 V 60Hz 15A and marked SJT or SVT etc DC POWER SUPPLY Maintenance GENERAL MAINTENANCE 1 Preventive maintenance Clean and re calibrate the instrument on a regular basis to keep the instrument looking nice and working will 2 Cleaning Remove any dirt dust and grime whenever they become noticeable on the outside cover with a soft cloth moist...

Page 6: ...eral Power Source Dimensions W x H x D Weight ACV 115 230 10 50 60Hz 9 5kg 230 x 170 x 310 mm ITEM PW 3063R PW 4063R 4 Digits 0 36 Green LED 0 05 3 digits 4 Digits 0 36 Red LED Tracking Operation Parallel Regulation Series and Supply Regulation Series Single Supply Regulation Line 0 01 3mV Load 0 01 5mV Line 0 01 5mA Load Regulation 300mV Line 0 01 3mV Load 0 01 5mV Slave tracking error 0 5 2 digi...

Page 7: ...ive output terminal of the fixed 5V 3A output black 3 5V output terminal Positive output terminal of the fixed 5V 3A output red 4 Over load indicator 5V 3A over load red LED indicator 5 Master output terminal Negative output terminal of the MASTER 0 32V 0 6A output black 6 Master GND terminal Ground terminal of the master output green 7 Master output terminal Positive output terminal of the master...

Page 8: ...digits Green 0 56 LED 3063R Slave voltage indicator display in full 4 digits Green 0 36 LED 4063R 17 Slave current indicator display in full 3 digits Red 0 56 LED 3063R Slave current indicator display in full 4 digits Red 0 36 LED 4063R 18 Slave voltage adjustment knob For adjusting slave output voltage when slave is under C V Mode 19 Slave current adjustment knob For adjusting slave output curren...

Page 9: ...ed input voltage is set to the voltage marked on the holder to the mark on the rear panel E The input power voltage indicator The mark show the input line voltage been set When the unit been shipped from factory 6 DC POWER SUPPLY D E Fuse description 1 2 2 PW 4063R 1 PW 3063R Voltage Hz Fuse 110 120V 50 60 T10A 220 240V 50 60 T6A Voltage Hz Fuse 110 120V 50 60 T10A 220 240V 50 60 T6A ...

Page 10: ...nd output current NOTE The power supply can automatically operate between constant voltage and constant current by quickly responding to the load changes when the C C LED Red light up the C V LED green will be off and vice versa DC POWER SUPPLY B Operation Modes of 3063R The power supply can be operated alone or connected two or more units in serial to obtain a higher voltage Max 240V or in parall...

Page 11: ...ut terminal automatically The parallel output are generated from the master output for both and termimals The output voltage is the same as the master set value and the output current is twice the master output current setting 3 1 Set the output mode switch 25 to parallel mode and the red LED 15 will light up 3 2 Be sure to turn both of the voltage adjustment knob 18 and current adjustment knob 19...

Page 12: ...ystem 5 3 The output voltage of the system is the same as the units been set The output current of the system is the sum of each unit WARNING The Max output current of the parallel system should never exceeds 24A 6 Fixed 5V 3A output This is the standard 5V 3A power output for use of TTL logic circuit When the load exceeds 3A the red overload LED will light up The output voltage will lower and the...

Page 13: ...nt of the system never exceeds 24A 6 Fixed 5V 3A output This is the standard 5V 3A power output for use of TTL logic circuit When the load exceed 3A the red overload LED will light up The output voltage will lower and the power supply will be under C C mode 4 1 Set all the 4063R which would be connected in serial operation under serial tracking mode as described on section 2 4 2 Connect the slave ...

Page 14: ... Control Knob Slave C V LED Slave C C Parallel LED Grounding Terminal Fixed overlood LED 4 Digits 0 36 Green LED 4 Digits 0 36 Red LED 10 Turn VR for Current Setting 10 Turn VR for Voltage Setting High Efficiency Heatsink Series LED Green Master Current Control Knob Master Voltage Control Knob Parallel LED Red Master output Master C V LED Master C C LED Grounding Terminal Fixed 5V 3A output Fixed ...

Page 15: ......

Page 16: ...TINSE0068S4 Ver 01 10 MAR ...

Reviews: