Pintek PW-3063R Instruction Manual Download Page 4

Notice Before Operation

DC POWER SUPPLY

1. Unpack the instrument:

After receipt of the instrument, immediately unpack and inspect it for any damage which 

might have been sustained during transportation or shortage of accessories. If any sign of 
damage or shortage of accessories are found, immediately notify the dealer.

2.Environments:

Operational temperature of the instrument is 10

 to 40

(50

 to 104

) at lower than 

90%R.H. Operation of the instrument outside of this temperature range may cause 
damage to the circuits.

3.Check the Line Voltage:

The instrument can operate on the line voltages list below and this voltage can be set by  
inserting the line voltage selector plugged in the corresponding position on the rear panel.
Before connection the power plug to an AC outlet, be sure to check the set up with line 
voltage.

1

Selector

Line Voltage

Fuse

115V

230V

100~125V  50/60Hz

220~240V  50/60Hz

PW-3063R

PW-4063R

T10A

T6A

T10A

T6A

Hints for operation:

1

Do not place heavy objects on this instrument.

2. Do not place a hot soldering iron on or near this instrument.
3. Never insert wires, pins or other metal object into ventilation fan.
4. Never move or pull the instrument with power cord or output lead, especially never move 

instrument when power cord or output lead is connected.

5. If the instrument is used in the way not specified in this manual, the protection provided 

by the equipment may be impaired.

WARNING

The following precautions must be observed to prevent electric shock.

* Disconnect the mains plug before and during fuse replacement.

1. To avoid electrical shock, only qualified personnel should operate this instrument.  
2. Do not open the cover of this instrument. Only qualified electrician should perform the 

needed services inside this instrument.

Summary of Contents for PW-3063R

Page 1: ...Model PW 3063R PW 4063R INSTRUCTION MANUAL DC POWER SUPPLY ...

Page 2: ......

Page 3: ...ion Description Operation Instruction A Setting the output voltage and output current B Operation Modes of 3063R C Operation Modes of 4063R D of 3063R 4063R 1 Symbol Description 2 Front Panel 3 Rear Panel Description Front Panel Table of Contents 1 2 3 4 4 6 9 7 7 7 4 11 ...

Page 4: ...sure to check the set up with line voltage 1 Selector Line Voltage Fuse 115V 230V 100 125V 50 60Hz 220 240V 50 60Hz PW 3063R PW 4063R T10A T6A T10A T6A Hints for operation 1 Do not place heavy objects on this instrument 2 Do not place a hot soldering iron on or near this instrument 3 Never insert wires pins or other metal object into ventilation fan 4 Never move or pull the instrument with power c...

Page 5: ...No 18 AWM minimum The minimum electrical ratings shall be 125 V 60Hz 15A and marked SJT or SVT etc DC POWER SUPPLY Maintenance GENERAL MAINTENANCE 1 Preventive maintenance Clean and re calibrate the instrument on a regular basis to keep the instrument looking nice and working will 2 Cleaning Remove any dirt dust and grime whenever they become noticeable on the outside cover with a soft cloth moist...

Page 6: ...eral Power Source Dimensions W x H x D Weight ACV 115 230 10 50 60Hz 9 5kg 230 x 170 x 310 mm ITEM PW 3063R PW 4063R 4 Digits 0 36 Green LED 0 05 3 digits 4 Digits 0 36 Red LED Tracking Operation Parallel Regulation Series and Supply Regulation Series Single Supply Regulation Line 0 01 3mV Load 0 01 5mV Line 0 01 5mA Load Regulation 300mV Line 0 01 3mV Load 0 01 5mV Slave tracking error 0 5 2 digi...

Page 7: ...ive output terminal of the fixed 5V 3A output black 3 5V output terminal Positive output terminal of the fixed 5V 3A output red 4 Over load indicator 5V 3A over load red LED indicator 5 Master output terminal Negative output terminal of the MASTER 0 32V 0 6A output black 6 Master GND terminal Ground terminal of the master output green 7 Master output terminal Positive output terminal of the master...

Page 8: ...digits Green 0 56 LED 3063R Slave voltage indicator display in full 4 digits Green 0 36 LED 4063R 17 Slave current indicator display in full 3 digits Red 0 56 LED 3063R Slave current indicator display in full 4 digits Red 0 36 LED 4063R 18 Slave voltage adjustment knob For adjusting slave output voltage when slave is under C V Mode 19 Slave current adjustment knob For adjusting slave output curren...

Page 9: ...ed input voltage is set to the voltage marked on the holder to the mark on the rear panel E The input power voltage indicator The mark show the input line voltage been set When the unit been shipped from factory 6 DC POWER SUPPLY D E Fuse description 1 2 2 PW 4063R 1 PW 3063R Voltage Hz Fuse 110 120V 50 60 T10A 220 240V 50 60 T6A Voltage Hz Fuse 110 120V 50 60 T10A 220 240V 50 60 T6A ...

Page 10: ...nd output current NOTE The power supply can automatically operate between constant voltage and constant current by quickly responding to the load changes when the C C LED Red light up the C V LED green will be off and vice versa DC POWER SUPPLY B Operation Modes of 3063R The power supply can be operated alone or connected two or more units in serial to obtain a higher voltage Max 240V or in parall...

Page 11: ...ut terminal automatically The parallel output are generated from the master output for both and termimals The output voltage is the same as the master set value and the output current is twice the master output current setting 3 1 Set the output mode switch 25 to parallel mode and the red LED 15 will light up 3 2 Be sure to turn both of the voltage adjustment knob 18 and current adjustment knob 19...

Page 12: ...ystem 5 3 The output voltage of the system is the same as the units been set The output current of the system is the sum of each unit WARNING The Max output current of the parallel system should never exceeds 24A 6 Fixed 5V 3A output This is the standard 5V 3A power output for use of TTL logic circuit When the load exceeds 3A the red overload LED will light up The output voltage will lower and the...

Page 13: ...nt of the system never exceeds 24A 6 Fixed 5V 3A output This is the standard 5V 3A power output for use of TTL logic circuit When the load exceed 3A the red overload LED will light up The output voltage will lower and the power supply will be under C C mode 4 1 Set all the 4063R which would be connected in serial operation under serial tracking mode as described on section 2 4 2 Connect the slave ...

Page 14: ... Control Knob Slave C V LED Slave C C Parallel LED Grounding Terminal Fixed overlood LED 4 Digits 0 36 Green LED 4 Digits 0 36 Red LED 10 Turn VR for Current Setting 10 Turn VR for Voltage Setting High Efficiency Heatsink Series LED Green Master Current Control Knob Master Voltage Control Knob Parallel LED Red Master output Master C V LED Master C C LED Grounding Terminal Fixed 5V 3A output Fixed ...

Page 15: ......

Page 16: ...TINSE0068S4 Ver 01 10 MAR ...

Reviews: