Kerosene Radiant Heater User’s Manual
NEVER LEAVE HEATER UNATTENDED WHILE BURNING
OR WHILE CONNECTED TO A POWER SOURCE
8
OPERATION (CONT.)
Starting the Heater (Ignition):
1. Fill the tank with Kerosene or other
approved fuel until needle on fuel gauge
points to “F”.
2. Replace fuel cap and tighten firmly.
3. Connect the heater to a three prong
(grounded) power source. You must use a
three prong (grounded) extension cord that
is at least 1.8 meters long and is a minimum
of 14 AWG rating.
NOTE: On first ignition or after refueling, you
may hear a grinding sound just before ignition.
This is the fuel pump removing the air from
the fuel line. Your heater will start up within
seconds. If it does not start repeat
start-up procedures with fuel gauge reading at
least 1/2 tank.
NOTE: Smoking may occur on first ignition.
NOTE: The electrical components of these
heaters are protected by a fuse mounted in
the PC board. If the heater fails to ignite,
check this fuse first and replace if necessary.
Also check the power source to be sure the
proper voltage is being provided to the
heater.
1. Complete steps 1-3 above.
2. Push the power switch to the “ON” position.
The power indicator lamp will light and
heater will ignite (see Figure 10).
Stopping the Heater (Cool Down):
1. Turn the power switch to the “OFF” position.
Combustion will stop and the Cooling Cycle
will begin.
- 80-OFR-O: approx. 5 mins
- 125-OFR-O: approx 3 mins
When the Cooling Cycle is complete the fan
will stop running and it will be safe to unplug
the heater.
NOTE: Unplugging the heater before the
Cooling Cycle has been completed may cause
overheating, possible damage to the heater and
heat plate.
Restarting the Heater:
1. Wait ten seconds after Cooling Cycle has
been completed.
2. Follow all start-up procedures above.
Electrical Outlet (80-OFR-O Only):
- Never plug an appliance with more than a 5
amp rating into this outlet (see Figure 11).
- Always keep outlet covered when not in use
Figure 10
Power Switch
Figure 11
Electrical Outlet
80-OFR-O Only
DO NOT disconnect
heater from power
source before
cooling cycle has been completed.
WARNING