background image

© 2018 Pinnacle Climate Technologies, Inc. 

Kerosene Radiant Heater User’s Manual 

NEVER LEAVE HEATER UNATTENDED WHILE BURNING 

OR WHILE CONNECTED TO A POWER SOURCE

17

LIMITED WARRANTY

Pinnacle Climate Technnologies, Inc.

 warrants this heater 

to the original retail purchaser only, to be free from 

defects in material and workmanship for a period of one 

(1) year from the date of initial purchase. This product 

must be properly installed, maintained and operated in 

accordance with the instructions provided.

Pinnacle Climate Technnologies, Inc. 

requires reasonable 

proof of your date of purchase from an authorized retailer 

or distributor.  Therefore, you should keep your sales slip, 

invoice or cancelled check from the original purchase.  

This Limited Warranty shall be limited to the repair or 

replacement of parts, which prove defective under normal 

use and service within the warranty period, and which 

Pinnacle Climate Technnologies, Inc.

 shall determine at 

its reasonable discretion. 

This warranty does not apply to products purchased for 

rental use. 

This Limited Warranty does not cover any failures or 

operating difficulties due to normal wear and tear, 

accident, abuse, misuse, alteration, misapplication, 

improper installation or improper maintenance and 

service by you or any third party.  Failure to perform 

normal and routine maintenance on the heater, shipping 

damage, damage related to insects, birds or animals 

of any kind, and damage due to weather conditions 

are also not covered. In addition, the Limited Warranty 

does not cover damage to the finish, such as scratches, 

dents, discoloration, rust or other weather damage, after 

purchase. 

All transportation costs for the return of damaged 

product or parts will be the responsibility of the 

purchaser. Upon receipt of damaged item, 

Pinnacle 

Climate Technnologies, Inc. 

will examine the item and 

determine if defective. 

Pinnacle Climate Technnologies, 

Inc. 

will repair or replace and return the item, freight pre-

paid.

If 

Pinnacle Climate Technnologies, Inc. 

finds the item 

to be in normal operating condition, or not defective 

the item will be returned freight collect. This Limited 

Warranty is in lieu of all other express warranties. 

Pinnacle Climate Technnologies, Inc.

 disclaims all 

warranties for products that are purchased from sellers 

other than authorized dealers or distributors. 

AFTER THE PERIOD OF THE ONE (1) YEAR EXPRESS 

WARRANTY EXPIRES, 

Pinnacle Climate Technnologies, 

Inc. 

DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, 

INCLUDING WITHOUT LIMITATION THE IMPLIED 

WARRANTIES OF MERCHANTABILITY AND FITNESS 

FOR A PARTICULAR APPLICATION. FURTHER, 

Pinnacle 

Climate Technnologies, Inc. 

SHALL HAVE NO LIABILITY 

WHATSOEVER TO PURCHASER OR ANY THIRD PARTY 

FOR ANY SPECIAL, INDIRECT, PUNITIVE INCIDENTAL, 

OR CONSEQUENTIAL DAMAGES. 

Pinnacle Climate 

Technnologies, Inc. 

assumes no responsibility for any 

defects caused by third parties. This Limited Warranty 

gives the purchaser specific legal rights; a purchaser 

may have other rights depending upon where he or she 

lives. Some states do not allow the exclusion or limitation 

of special, incidental or consequential damages, or 

limitations on how long a warranty lasts, so the above 

exclusion and limitations may not apply to you.  

Pinnacle Climate Technnologies, Inc. 

does not 

authorize any person or company to assume for it any 

other obligation or liability in connection with the sale, 

installation, use, removal, return or replacement of its 

equipment, and no such representations are binding on 

Pinnacle Climate Technnologies, Inc.

Always be sure to specify the model number and serial 

number when making any claim with 

Pinnacle Climate 

Technnologies, Inc. 

For your convenience, use the space 

provided below to list this information.

Model #:________________________________
Serial #:________________________________
Date of Purchase: ________________________

Locating Your Serial Number:

Your serial number can be found on a blue label on the left side cover. It will begin with the letter “S” followed 

by 9 digits. For Example: S160901126. Have your Serial Number ready before calling customer service at 800-

641-6996.

XXXXXXXXXX

Serial Number Label

Summary of Contents for REMINGTON REM-125-OFR-B

Page 1: ...QUATELY VENTILATED BUILDINGS OR STRUCTURES UNDER CONSTRUCTION ALTERATION OR REPAIR This is an unvented portable heater that uses air Oxygen from within the area in which it is used Failure to provide...

Page 2: ...ATER WHEN THE CHAMBER IS HOT WARNING WARNING WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD Keep combustibles such as building materials paper or cardboard a safe distance away from the heater as r...

Page 3: ...The products described in this manual are kerosene direct fired forced air heaters Kerosene forced air heaters are primarily intended for use for temporary heating of buildings under construction alte...

Page 4: ...tion Gal Hr L Hr 0 63 2 38 0 85 3 22 Fuel Tank Capacity Gal L 4 15 14 14 53 Max Operating Hours 7 2 7 Volts AC Hz 120 V 60 Hz 120 V 60 Hz Amps 3 15 3 15 Heating Area ft 2 2000 4198 Specifications subj...

Page 5: ...Attach the handle while still in the box for easier unpacking see Figures 1 and 2 Carry Handle 1 Black Screws 2 80 OFR B 1 Remove existing screws from shell ring on either side of heater see Figure 3...

Page 6: ...ed see Figure 8 4 Attach Radiant Visors to the top and bottom rear of the Radiant Cone Assembly using extra screws included 5 Attach top safety guard using the two outer most extra screws on the top o...

Page 7: ...ct sunlight or near a source of heat NEVER use Kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD Kerosene WILL NOT BURN PROPERLY IN THIS HEATER NOTE Kerosen...

Page 8: ...fails to ignite check this fuse first and replace if necessary Also check the power source to be sure the proper voltage is being provided to the heater 1 Complete steps 1 3 above 2 Push the power swi...

Page 9: ...SPARK PLUG Clean and re gap every 600 hours of operation or replace as needed After removing the Spark Plug clean the terminals with a wire brush Re gap the terminals to 0 140 3 5 mm see Figure 12 FAN...

Page 10: ...ozzle in clean Kerosene or diesel to help loosen any particles see Figure 14a and 14b PHOTOCELL The photocell should be cleaned at least once per heating season or more depending on conditions Use a c...

Page 11: ...te Technologies Inc Kerosene Radiant Heater User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 11 125 OFR B WIRING DIAGRAMS AC 120V 60Hz AC 250V 3 15A ELECT...

Page 12: ...lug 3 Clean replace Fuel Filter 4 Clean replace Nozzle 5 Rinse out fuel tank with clean fresh Kerosene diesel 6 Inspect all electrical connections See Wiring Diagrams Page 11 7 Re attach Transformer w...

Page 13: ...s Inc Kerosene Radiant Heater User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 13 EXPLODED VIEW 25 23 24 9 21 22 20 19 26 10 7 28 6 4 3 1 2 27 8 12 13 29...

Page 14: ...0650 9 Ignitor 75 025 0120 10 Main PCB Assembly 75 025 0400 11 Tip Over Sensor 75 051 0200 12 Cooling Motor Assembly 75 047 0250 13 Cooling Fan 75 047 0200 14 Handle 75 001 0060 15 Temperature Limit...

Page 15: ...erosene Radiant Heater User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 15 1 2 4 3 5 6 7 8 9 10 11 12 13 14 15 16 17 18 24 20 22 21 30 23 26 19 34 27 29 4...

Page 16: ...ump 72 027 0100 11 Main PCB and Fuse 72 025 0450 12 Tip Over Sensor 75 051 0200 13 Power Cord 72 032 0150 14 Power Switch 72 012 0120 15 Back Cover 72 013 0110 16 Panel sub PCB 72 014 0100 17 Blower M...

Page 17: ...If Pinnacle Climate Technnologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other expres...

Page 18: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 800 641 6996 Fax 320 251 2922 Web www remingtonheater com Email info pinnacleclimate com 2018 Pinnacle Climate Technologies Inc...

Page 19: ...E INT RIEUR PERMIS SEULEMENT POUR LE CHAUFFAGE TEMPORAIRE DES STRUCTURES OU DES B TIMENTS BIEN VENTIL S EN COURS DE CONSTRUCTION DE MODIFICATION OU DE R PARATION Ceci est une chaufferette portative no...

Page 20: ...NT NE PAS METTRE EN MARCHE LA CHAUFFERETTE LORSQUE LA CHAMBRE DE COMBUSTION EST CHAUDE AVERTISSEMENT RISQUE D INCENDIE DE BR LURE D INHALATION ET D EXPLOSION Garder les mat riaux combustibles tels que...

Page 21: ...V TEMENTS OU DE TOUT MAT RIAU COMBUSTIBLE Les produits d crits dans ce manuel sont des chaufferettes feu direct et air puls aliment es au k ros ne Les chaufferettes air forc au k ros ne sont principal...

Page 22: ...20 V 60 Hz Amp res 3 15 3 15 Surface chauff e m2 186 390 Sp cifications sujettes modification sans pr avis CARACT RISTIQUES JAUGE DE PRESSION DU CARBURANT DERRI RE LE CAPOT AMOVIBLE ENVELOPPE ANNEAU D...

Page 23: ...haufferette est encore dans la bo te pour faciliter le d ballage voir les Figures 1 et 2 Figure 1 Figure 2 Poign e 1 Vis noires 2 80 OFR B 1 Retirer les vis existantes de l anneau de chaque c t de la...

Page 24: ...es plaques de rayonnement sur la partie arri re sup rieure et inf rieure du c ne de rayonnement l aide des vis suppl mentaires incluses 5 Fixer la protection de s curit sup rieure l aide des deux vis...

Page 25: ...soleil ou proximit d une source de chaleur NE JAMAIS utiliser du k ros ne entrepos la saison pr c dente pour la saison suivante Le k ros ne se d t riore avec le temps LE VIEUX K ROS NE NE BR LE PAS CO...

Page 26: ...sible et le remplacer le cas ch ant V rifier galement la source d alimentation pour s assurer de la tension correcte 1 Compl ter les tapes 1 3 ci dessus 2 Placer l interrupteur la position de MARCHE L...

Page 27: ...l cartement entre les lectrodes toutes les 600 heures de fonctionnement ou remplacer s il y a lieu Apr s l enl vement de la bougie nettoyer les bornes avec une brosse m tallique R gler l cartement des...

Page 28: ...4a et 14b CELLULE PHOTO LECTRIQUE La cellule photo lectrique doit tre nettoy e au moins une fois par saison de chauffage ou plus fr quemment suivant les conditions Utiliser un coton tige tremp dans de...

Page 29: ...INCIPAL MOTEUR DU VENTILATEUR MOTEUR DE REFROIDISSEMENT POMPE CCI DU PANNEAU VOYANT DE FONCTIONNEMENT VOYANT D ERREUR INTERRUPTEUR ANTI RENVERSEMENT LIMITEUR DE TEMP RATURE CELLULE PHOTO LECTRIQUE PRI...

Page 30: ...e 3 Nettoyer remplacer le filtre carburant 4 Nettoyer remplacer la buse 5 Rincer le r servoir de carburant avec du k ros ne diesel neuf propre 6 V rifier toutes les connexions lectriques Voir les Sch...

Page 31: ...ur de la chaufferette au k ros ne NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU ELLE BR LE OU QU ELLE EST BRANCH E UNE SOURCE DE COMBUSTIBLE 13 VUE CLAT E 25 23 24 9 21 22 20 19 26 10 7...

Page 32: ...e 75 027 0650 9 Allumeur 75 025 0120 10 Carte de circuits imprim s principale 75 025 0400 11 Interrupteur anti basculement 75 051 0200 12 Moteur de refroidissement 75 047 0250 13 Ventilateur de refroi...

Page 33: ...a chaufferette au k ros ne NE JAMAIS LAISSER UNE CHAUFFERETTE SANS SURVEILLANCE LORSQU ELLE BR LE OU QU ELLE EST BRANCH E UNE SOURCE DE COMBUSTIBLE 15 1 2 4 3 5 6 7 8 9 10 11 12 13 14 15 16 17 18 24 2...

Page 34: ...rburant 72 027 0100 11 Carte de circuits imprim s principale et fusible 72 025 0450 12 Interrupteur anti basculement 75 051 0200 13 Cordon lectrique 72 032 0150 14 Interrupteur d alimentation 72 012 0...

Page 35: ...acle Climate Technologies Inc r parera ou remplacera et retournera l article en port pay Si Pinnacle Climate Technnologies Inc d termine que l article est dans un tat normal d utilisation ou n est pas...

Page 36: ...Industrial Blvd 101 Sauk Rapids MN 56379 USA Num ro sans frais 800 641 6996 T l copieur 320 251 2922 Web www remingtonheater com Courriel info pinnacleclimate com 2018 Pinnacle Climate Technologies In...

Reviews: