background image

© 2017, Pinnacle Climate Technologies, Inc. 

Kerosene Radiant Heater User’s Manual 

NEVER LEAVE HEATER UNATTENDED WHILE BURNING 

OR WHILE CONNECTED TO A POWER SOURCE

13

Parts List: 70-SS

Item #

Description

70-SS

1

Fuel Filter

75-023-0285

2

Fuel Line

75-024-0510

3

Fuel Gauge

75-022-0200

4

Fuel Cap

70-006-0140

5

Cooling Fan Housing / Cooling Fan Housing Panel

75-011-0685 / 75-011-0690

6

Operating Switch

75-012-0110

7

Operating Switch Wire

75-012-0220

8

Electric Pump

75-027-0650

9

Ignitor

75-025-0120

10

Main PCB Assembly

75-025-0400

11

Tip-Over Sensor

75-051-0200

12

Cooling Motor Assembly

75-047-0250

13

Cooling Fan

75-047-0200

14

Handle 

75-001-0060

15

Temperature Limit Switch

75-040-0100

16

Heat Plate

75-012-0600

17

Shell Ring

75-011-0650

18

Safety Guard

75-012-0310

19

Burner Body

75-036-0180

20

Spark Plug

75-075-0200

21

Burner Blade

75-036-0120

22

Nozzle

75-036-0400

23

Nipple

75-040-0610

24

Diffusion Cap

75-036-0500

25

Blower Motor Assembly

75-045-0200

26

Photocell

75-038-0200

27

Return Pipe

75-055-0100

28

Return Hose

75-055-0200

29

Electronic Pump Bracket

75-027-0255

30

Heat Shield

75-012-0320

31

Fuel Pressure Gauge

70-028-0200

Summary of Contents for MASTER MH-125-OFR-A

Page 1: ...Safety Information FIRE BURN INHALATION AND EXPLOSION HAZARD Keep combustibles such as building materials paper or cardboard a safe distance away from the heater as recommended by these instruc tions...

Page 2: ...for temporary heating of buildings under construction alteration or repair Direct fired means that all of the combustion products of the heater enter the heated space This appliance is rated at 98 com...

Page 3: ...use with an external fuel tank Keep all combustible materials away from this heater Minimum Clearance From Combustibles 70 SS 125 OFR Top 4 ft 125 cm 6 ft 185 cm Sides 4 ft 125 cm 6 ft 185 cm Front 8...

Page 4: ...EAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 3 Features FUEL PRESSURE GAUGE BEHIND REMOVABLE COVER 70 SS 125 OFR Top Safety Guard Radiant Cone Front Safety Guard Radiant V...

Page 5: ...iver Figure 1 Figure 2 Attach the handle while still in the box for easier unpacking see Figure 2 Carry Handle 1 Black Screws 2 Step 1 Remove existing screws from shell ring on either side of heater s...

Page 6: ...attach wheels washers and nuts see Figure 6 2 Place main structure on wheel frame and fasten with long screws provided see Figure 7 3 Attach safety guard to front of heater with screws provided see F...

Page 7: ...in direct sunlight or near a source of heat NEVER use Kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD Kerosene WILL NOT BURN PROPERLY IN THIS HEATER NOTE...

Page 8: ...heater fails to ignite check this fuse first and replace if necessary Also check the power source to be sure the proper voltage is being provided to the heater 1 Complete steps 1 3 above 2 Push the p...

Page 9: ...ush with water use fresh Kerosene only SPARK PLUG Clean and re gap every 600 hours of operation or replace as needed After removing the Spark Plug clean the terminals with a wire brush Re gap the term...

Page 10: ...n clean Kerosene or diesel to help loosen any particles see Figure 14a and 14b PHOTOCELL The photocell should be cleaned at least once per heating season or more depending on conditions Use a cotton s...

Page 11: ...Spark Plug 3 Clean replace Fuel Filter 4 Clean replace Nozzle 5 Rinse out fuel tank with clean fresh Kerosene diesel 6 Inspect all electrical connections See Wiring Diagrams Page 11 7 Re attach Transf...

Page 12: ...imate Technologies Inc Kerosene Radiant Heater User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 125 OFR 11 Wiring Diagram AC 120V 60Hz AC 250V 3 15A ELECT...

Page 13: ...es Inc Kerosene Radiant Heater User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Exploded View 12 25 23 24 9 21 22 20 19 26 10 7 28 6 4 3 1 2 27 8 12 13 29...

Page 14: ...0 9 Ignitor 75 025 0120 10 Main PCB Assembly 75 025 0400 11 Tip Over Sensor 75 051 0200 12 Cooling Motor Assembly 75 047 0250 13 Cooling Fan 75 047 0200 14 Handle 75 001 0060 15 Temperature Limit Swit...

Page 15: ...Kerosene Radiant Heater User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 1 2 4 3 5 6 7 8 9 10 11 12 13 14 15 16 17 18 24 20 22 21 30 23 26 19 34 27 29 42...

Page 16: ...p 72 027 0100 11 Main PCB and Fuse 72 025 0450 12 Tip Over Sensor 75 051 0200 13 Power Cord 72 032 0150 14 Power Switch 72 012 0120 15 Back Cover 72 013 0110 16 Panel sub PCB 72 014 0100 17 Blower Mot...

Page 17: ...If Pinnacle Climate Technnologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other expres...

Page 18: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 800 779 3267 Fax 320 251 2922 Web www masterindustrialproducts com Email info pinnacleclimate com 2017 Pinnacle Climate Technologies Inc...

Reviews: