Maintenance: 70-SS / 125-OFR

Long Term Storage:

1.  Unscrew the fuel cap.

2.  Using an approved siphon, remove the 

Kerosene or diesel.

3.  Using a small amount of Kerosene or diesel, 

rinse and swirl the fuel inside the fuel tank

NOTE: NEVER MIX WATER WITH FUEL. It will 

cause rust inside the tank. 

4.  Empty the tank completely.

IMPORTANT: Never store leftover Kerosene 

between seasons, using old fuel can  

damage heater.

Store Heater in a dry, well ventilated area.

 - Be sure that the storage area is free of dust 

and corrosive vapors. Repack the heater 

in the original packaging and keep user’s 

manual in an easily accessible place.

Service:

DO NOT TAMPER WITH THE UNIT. HAVE AN 

EXPERIENCED SERVICEMAN MAKE ANY 

NECESSARY ADJUSTMENT OR REPAIRS.
We suggest following a maintenance schedule as 
follows:

FUEL / FUEL TANK:

Flush tank every 200 hours of operation or as 

needed. DO NOT flush with water, use fresh 

Kerosene only.

SPARK PLUG:

Clean and re-gap every 600 hours of operation 

or replace as needed. After removing the Spark 

Plug, clean the terminals with a wire brush.  

Re-gap the terminals to 0.140” (3.5 mm)  

(see Figure 12).

FAN BLADES:

The fan blades should be cleaned at least once 

per heating season, depending on conditions. 

Remove all accumulated dust and dirt with a 

burst of condensed air (see Figure 13).

PRESSURE ADJUSTMENTS:

Proper pressure is dependent on the fuel type the 

unit will be running. When smoking or non-ignition 

occurs, remove the lower panel. Locate the brass 

screw on the fuel pump to the left of the fuel line. 

The ideal pressure is 112 psi (7.9 kg/cm

2

).

 

If you are experiencing smoking or fuel 

dripping from the unit

,

 turn the screw clockwise 

1/8 to 1/4 of a turn to increase the fuel pressure 

until the unit is operating properly. 

If you are experiencing extended flames 

from the front of the unit,

 turn the screw 1/8 to 

1/4 of a turn counterclockwise to reduce the air 

pressure until the unit is operating properly.

TIP: Follow the long term storage 

instructions to flush the tank. 

Figure 13

Figure 12

70-SS

70-SS / 125-OFR

8

Never service 

heater while it is 

plugged in or hot!

WARNING

Summary of Contents for MASTER MH-125-OFR-A

Page 1: ...Safety Information FIRE BURN INHALATION AND EXPLOSION HAZARD Keep combustibles such as building materials paper or cardboard a safe distance away from the heater as recommended by these instruc tions...

Page 2: ...for temporary heating of buildings under construction alteration or repair Direct fired means that all of the combustion products of the heater enter the heated space This appliance is rated at 98 com...

Page 3: ...use with an external fuel tank Keep all combustible materials away from this heater Minimum Clearance From Combustibles 70 SS 125 OFR Top 4 ft 125 cm 6 ft 185 cm Sides 4 ft 125 cm 6 ft 185 cm Front 8...

Page 4: ...EAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 3 Features FUEL PRESSURE GAUGE BEHIND REMOVABLE COVER 70 SS 125 OFR Top Safety Guard Radiant Cone Front Safety Guard Radiant V...

Page 5: ...iver Figure 1 Figure 2 Attach the handle while still in the box for easier unpacking see Figure 2 Carry Handle 1 Black Screws 2 Step 1 Remove existing screws from shell ring on either side of heater s...

Page 6: ...attach wheels washers and nuts see Figure 6 2 Place main structure on wheel frame and fasten with long screws provided see Figure 7 3 Attach safety guard to front of heater with screws provided see F...

Page 7: ...in direct sunlight or near a source of heat NEVER use Kerosene that has been stored from one season to the next Kerosene deteriorates over time OLD Kerosene WILL NOT BURN PROPERLY IN THIS HEATER NOTE...

Page 8: ...heater fails to ignite check this fuse first and replace if necessary Also check the power source to be sure the proper voltage is being provided to the heater 1 Complete steps 1 3 above 2 Push the p...

Page 9: ...ush with water use fresh Kerosene only SPARK PLUG Clean and re gap every 600 hours of operation or replace as needed After removing the Spark Plug clean the terminals with a wire brush Re gap the term...

Page 10: ...n clean Kerosene or diesel to help loosen any particles see Figure 14a and 14b PHOTOCELL The photocell should be cleaned at least once per heating season or more depending on conditions Use a cotton s...

Page 11: ...Spark Plug 3 Clean replace Fuel Filter 4 Clean replace Nozzle 5 Rinse out fuel tank with clean fresh Kerosene diesel 6 Inspect all electrical connections See Wiring Diagrams Page 11 7 Re attach Transf...

Page 12: ...imate Technologies Inc Kerosene Radiant Heater User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 125 OFR 11 Wiring Diagram AC 120V 60Hz AC 250V 3 15A ELECT...

Page 13: ...es Inc Kerosene Radiant Heater User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE Exploded View 12 25 23 24 9 21 22 20 19 26 10 7 28 6 4 3 1 2 27 8 12 13 29...

Page 14: ...0 9 Ignitor 75 025 0120 10 Main PCB Assembly 75 025 0400 11 Tip Over Sensor 75 051 0200 12 Cooling Motor Assembly 75 047 0250 13 Cooling Fan 75 047 0200 14 Handle 75 001 0060 15 Temperature Limit Swit...

Page 15: ...Kerosene Radiant Heater User s Manual NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR WHILE CONNECTED TO A POWER SOURCE 1 2 4 3 5 6 7 8 9 10 11 12 13 14 15 16 17 18 24 20 22 21 30 23 26 19 34 27 29 42...

Page 16: ...p 72 027 0100 11 Main PCB and Fuse 72 025 0450 12 Tip Over Sensor 75 051 0200 13 Power Cord 72 032 0150 14 Power Switch 72 012 0120 15 Back Cover 72 013 0110 16 Panel sub PCB 72 014 0100 17 Blower Mot...

Page 17: ...If Pinnacle Climate Technnologies Inc finds the item to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other expres...

Page 18: ...1 Industrial Blvd 101 Sauk Rapids MN 56379 USA Toll Free 800 779 3267 Fax 320 251 2922 Web www masterindustrialproducts com Email info pinnacleclimate com 2017 Pinnacle Climate Technologies Inc...

Reviews: