App
Exit technician menu.
Application registration
Enter the user menu using Master user code and press
ENTR
NEXT
ENTR
Connection type
NET4PRO
Select the NET4PRO module and press ENTR (note – even though there is no NET4PRO
module on the system, this is a necessary parameter for proper functioning with CLH4x2).
•
Select Cloud Registration.
•
Write down the resulting code.
•
In the application, select Add a new system (+).
•
Enter the received pairing code.
•
Make sure the pairing was successful.
•
Exit user menu.
Tests
Test the alarm system for sending events to the monitoring center and the application – Arm
your system, trigger alarms by opening the main door or in front of motion detectors, trigger
a duress alarm, test faults, etc.
Confirm that the events are received properly and in chronological order at the monitoring
center and/or in the application.
If there is more than one communication channel, disconnect the main channel, trigger some
events in the alarm system, and make sure they are received at the monitoring center through
the backup channel.
Specifications
Cellular communication channel
Technology
4G (according to the installed cellular module)
SIM
One or two
Network communication channel
Interface
Ethernet 10/100
Connection
RJ45
Interface with the alarm system
Serial
Input Power:
10VDC to 14VDC
Current Consumption:
50mA – without cellular module
300mA - with cellular module
Weight:
350 grams
Dimensions:
90x90x40 mm
Ordering information: P/N 8300080
P/N: xxxxxxxx
Revision: B en, Oct 2022