background image

All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made
for internal purposes.

Suggestions and comments for improving this documentation will be gratefully received.

Pilz

®

, PIT

®

, PMI

®

, PNOZ

®

, Primo

®

, PSEN

®

, PSS

®

, PVIS

®

, SafetyBUS p

®

, SafetyEYE

®

,

SafetyNET p

®

, the spirit of safety

®

 are registered and protected trademarks of

Pilz GmbH & Co. KG in some countries.

Summary of Contents for PSSnet SLL 4T 1FMMSC

Page 1: ...Industrial Ethernet Switches PSSnet S PSSnet SLL Series Devices Unmanaged Ethernet Switches Installation Mat No 22751 EN 01...

Page 2: ...de for internal purposes Suggestions and comments for improving this documentation will be gratefully received Pilz PIT PMI PNOZ Primo PSEN PSS PVIS SafetyBUS p SafetyEYE SafetyNET p the spirit of saf...

Page 3: ...SFP modules if present 13 2 1 3 Connecting the terminal block for the supply voltage and the grounding 13 2 1 4 Mounting the device on the DIN rail 13 2 1 5 Dimensions 15 2 1 6 Installing the terminal...

Page 4: ...ied out Note Contains important information on the product on how to manage the product or on the respective section of the documentation to which your special attention is being drawn Certified usage...

Page 5: ...01 4 b of the National Electrical Code NFPA 70 and in accordance with the authority having jurisdiction Only switch on the device when the housing is closed Shielding ground Beware of possible short c...

Page 6: ...in the care and use of appropriate safety equipment in accordance with the current standards of safety engineering X trained in providing first aid General safety instructions Electricity is used to...

Page 7: ...he regulations of member states relating to radio interference from motor vehicles Certified devices are marked with an e1 type approval indicator In accordance with the above named EU directive s the...

Page 8: ...and uses high frequencies and can radiate same and if it is not installed and used in accordance with this operating manual it can cause radio transmission interference The use of this device in a li...

Page 9: ...cket and one 100 Mbit s F O port 100BASE FX SC con nection Mount the devices by X simply snapping them onto a DIN rail Depending on the device variant you can choose various media to connect terminal...

Page 10: ...ata applies in a cross variant manner The devices comply with the specifications of the standard s X ISO IEC 8802 03 10BASE T 100BASE TX X ISO IEC 8802 03 100BASE FX Variant 10 100 Mbit s TP RJ45 100...

Page 11: ...or operation The following steps should be performed to install and configure a switch X Unpacking and checking X Connecting the terminal block for the supply voltage and the grounding X Mounting the...

Page 12: ...voltage and the grounding A 3 pin terminal block is used for the grounding and for connecting the supply voltage Warning Only connect a supply voltage that corresponds to the type plate of your device...

Page 13: ...The shielding ground of the connectable twisted pair lines is connected to the ground connection as a conductor Mount the device on a 35 mm DIN rail in accordance with DIN EN 60175 Attach the upper s...

Page 14: ...cting the voltage supply via the terminal block you start the opera tion of the device 2 1 7 Connecting the data lines You can connect terminal devices and other segments at the ports of the de vice v...

Page 15: ...terminal devices or inde pendent network segments in compliance with the IEEE 802 3 100BASE FX standard These ports support X Full duplex mode Note Make sure that the SM ports are only connected with...

Page 16: ...t status LEDs for Fast Ethernet TP ports 2 Port status LEDs for Gigabit Ethernet TP ports LED Display Color Activity Meaning P Power Green Lights up Supply voltage is on None Supply voltage is too low...

Page 17: ...Disassembly 2 3 1 Removing the device from the DIN rail To take the device off the DIN rail insert a screwdriver horizontally un der the housing into the locking slide pull it without tipping the scre...

Page 18: ...en incoming voltage and housing Potential difference from incoming voltage 24 V DC 32 V DC Potential difference from incoming voltage ground 32 V DC Environment Storage temperature ambient air 40 C to...

Page 19: ...Hz to 150 Hz 1 5 g at 200 Hz to 250 Hz IEC 60068 2 6 resonance search resonance dwell test Fc 2 Hz to 13 2 Hz with 1 mm ampli tude 0 7 g at 13 2 Hz to 100 Hz Shock IEC 60068 2 27 test Ea 15 g at 11 ms...

Page 20: ...1998 Safety for Industrial Control Equipment EN 55022 2006 IT equipment radio interference characteristics EN 61000 6 2 2005 Generic norm immunity in industrial environments EN 61131 2 2003 Programmab...

Page 21: ...nical queries please contact your local Pilz distributor or Pilz office You can find the addresses of our distributors on the Internet www pilz com Our support line is also at your disposal X Tel 49 7...

Page 22: ...22751 EN 01 2010 03 Printed in Germany Pilz GmbH Co KG 2010...