PSEN sl-0.5p 1.1
Operating Manual PSEN sl-0.5p 1.1
21904-EN-10
8
Warranty and liability
All claims to warranty and liability will be rendered invalid if
}
The product was used contrary to the purpose for which it is intended
}
Damage can be attributed to not having followed the guidelines in the manual
}
Operating personnel are not suitably qualified
}
Any type of modification has been made (e.g. exchanging components on the PCB
boards, soldering work etc.).
Disposal
}
In safety-related applications, please comply with the mission time T
M
in the safety-re-
lated characteristic data.
}
When decommissioning, please comply with local regulations regarding the disposal of
electronic devices (e.g. Electrical and Electronic Equipment Act).
For your safety
DANGER!
Risk to life due to manipulation/defeat of the safeguard
If replacement actuators are obtained, these must be installed as described
in the chapter entitled Installation.
If replacement actuators are used manipulatively or the function of the safe-
guard is defeated, there is a risk to life when operating the plant or machine!
This must be considered in the operator's hazard assessment and the oper-
ator must define appropriate measures to exclude manipulation.
}
Do not remove the connector's protective cap until you are just about to connect the
unit. This will prevent potential contamination.
Unit features
}
Transponder technology for presence detection
}
Device types Pilz coding type:
–
PSEN sl-0.5p 1.1: coded
}
different actuators available (see
–
Standard actuator PSEN sl-0.5
–
free-moving actuator PSEN sl-0.5fm for special applications with higher tolerance
compensation
}
Dual-channel operation
}
2 safety outputs
}
2 safety inputs for series connection of multiple safety switches
}
1 signal output
}
Magnetic guard locking for process protection
}
1 input to switch the locking magnet on/off