![Pilz PSEN sl-0.5p 1.1 Operating Manual Download Page 33](http://html1.mh-extra.com/html/pilz/psen-sl-0-5p-1-1/psen-sl-0-5p-1-1_operating-manual_1556616033.webp)
PSEN sl-0.5p 1.1
Operating Manual PSEN sl-0.5p 1.1
21904-EN-10
33
Safety characteristic data
NOTICE
You must comply with the safety-related characteristic data in order to
achieve the required safety level for your plant/machine.
Operating
Mode
EN ISO
13849-1:
2015
PL
EN ISO
13849-1:
2015
Category
EN 62061
SIL CL
EN 62061
PFH
D
[1/h]
IEC 61511
SIL
IEC 61511
PFD
EN ISO
13849-1:
2015
T
M
[year]
2-ch. OSSD
PL e
Cat. 4
SIL CL 3
3,29E-09
SIL 3
1,72E-04
20
All the units used within a safety function must be considered when calculating the safety
characteristic data.
INFORMATION
A safety function's SIL/PL values are
not
identical to the SIL/PL values of
the units that are used and may be different. We recommend that you use
the PAScal software tool to calculate the safety function's SIL/PL values.
Order reference
Order reference for safety gate system
Product type
Features
Connection
type
Order No.
PSEN sl-0.5p 1.1 / PSEN sl-0.5 1 unit
Safety gate system, coded M12, 8-pin con-
nector
570 500
PSEN sl-0.5p 1.1 / PSEN sl-0.5fm 1 unit
Safety gate system,
coded, with free-moving
actuator
M12, 8-pin con-
nector
570 560
Accessories
Product type
Features
Order no.
PSEN sl bracket swing door
Mounting bracket for swing gates and folding gates
570 550
PSEN sl bracket sliding door
Mounting bracket for sliding gates
570 551