Pilz PSEN op2.1 L- Operating Manual Download Page 4

PSEN op2.1 L­/ 2.2 T­Muting Set

Operating Manual PSEN op2.1 L­/ 2.2 T­Muting Set
1003535­EN­01

4

Introduction

Validity of documentation

This documentation is valid for the product PSEN op2.1 L­Muting Set. It is valid until new
documentation is published.

This operating manual explains the function and operation, describes the installation and
provides guidelines on how to connect the product.

Using the documentation

This document is intended for instruction. Only install and commission the product if you
have read and understood this document. The document should be retained for future ref­
erence.

Definition of symbols

Information that is particularly important is identified as follows:

DANGER!

This warning must be heeded! It warns of a hazardous situation that poses
an immediate threat of serious injury and death and indicates preventive
measures that can be taken.

WARNING!

This warning must be heeded! It warns of a hazardous situation that could
lead to serious injury and death and indicates preventive measures that can
be taken.

CAUTION!

This refers to a hazard that can lead to a less serious or minor injury plus
material damage, and also provides information on preventive measures
that can be taken.

NOTICE

This describes a situation in which the product or devices could be dam­
aged and also provides information on preventive measures that can be
taken. It also highlights areas within the text that are of particular import­
ance.

Summary of Contents for PSEN op2.1 L-

Page 1: ...PSEN op2 1 L 2 2 T Muting Set Operating Manual 1003535 EN 01 PSEN sensor technology...

Page 2: ...es may be made for internal purposes Suggestions and comments for improving this documentation will be gratefully received Pilz PIT PMI PNOZ Primo PSEN PSS PVIS SafetyBUS p SafetyEYE SafetyNET p the s...

Page 3: ...w 5 Safety 6 Intended use 6 Safety regulations 8 Use of qualified personnel 8 Warranty and liability 8 Disposal 8 Installation and wiring 8 Installation 8 Wiring 9 Commissioning 11 Orientation 11 LED...

Page 4: ...Information that is particularly important is identified as follows DANGER This warning must be heeded It warns of a hazardous situation that poses an immediate threat of serious injury and death and...

Page 5: ...N op2 4 L Reflector 2 x PSEN op muting bracket kit The muting sets are suitable for expanding all safety light grids in the PSEN op4B 1 Series PSEN op2B 1 Series PSEN op4F A Series PSEN op4H A Series...

Page 6: ...PSEN op2B 2 050 1 PSEN op4F A 14 030 1 PSEN op4H A 14 030 1 PSEN op4B 3 080 1 PSEN op2B 3 080 1 PSEN op4F A 14 045 1 PSEN op4H A 14 045 1 PSEN op4B 4 090 1 PSEN op2B 4 090 1 PSEN op4F A 14 060 1 PSEN...

Page 7: ...EN op4F A 14 105 1 PSEN op4H A 14 105 1 PSEN op4F A 14 120 1 PSEN op4H A 14 120 1 PSEN op4F A 14 135 1 PSEN op4H A 14 135 1 PSEN op4F A 14 150 1 PSEN op4H A 14 150 1 PSEN op4F A 14 165 1 PSEN op4H A 1...

Page 8: ...plicable to the specific application Warranty and liability All claims to warranty and liability will be rendered invalid if The product was used contrary to the purpose for which it is intended Damag...

Page 9: ...nting profiles should be at the same height 1 2 1 Mounting profile for attaching the muting sensor 2 Safety light grid on mounting surface Fix the muting sensor with the small plates to the mounting p...

Page 10: ...Pin 2 Muting 1 of connector 2 Wiring of muting sensor A2 on Pin 2 Muting 1 of connector 3 Wiring of muting sensor B1 on Pin 4 Muting 2 of connector 4 Wiring of muting sensor B2 on Pin 4 Muting 2 of co...

Page 11: ...es 2 and 6 to OFF If you are using the PSEN op2 1 T Muting Set set DIP switches 2 and 6 to ON 3 Use the LED to check the alignment of the muting sensors 4 Modify the position of the muting sensors on...

Page 12: ...id must be in normal operation If any of these requirements are not met the safety light grid switches immediately to a safe condition when supply voltage is switched on Checking the safety light grid...

Page 13: ...ight grid must light The red LEDs on the muting sensors must light The OSSDs must be switched off The monitored machine must be shut down Set muting timeout Time monitoring for the muting function can...

Page 14: ...PSEN op2 1 T Muting Set 4 1 2 3 4 1 2 3 5 Legend in mm 1 Width of muting sensor 35 2 Width of PSEN op muting bracket kit 55 5 3 Length of active muting arm PSEN op2 3 L Reflex 294 4 Width of the sock...

Page 15: ...ptical Electrical data 630820 630821 Supply voltage Voltage 24 0 V 24 0 V Kind DC DC Voltage tolerance 20 20 20 20 Protection class 1 1 Optical data 630820 630821 Operating range 0 5 3 0 m 0 5 3 0 m U...

Page 16: ...aterial Top Aluminium Aluminium Dimensions Height 60 0 mm 60 0 mm Width 355 3 mm 655 1 mm Depth 40 0 mm 40 0 mm Weight 1 100 g 1 800 g PSEN op2 3 L Reflex and PSEN op2 4 L Reflector General 630822 630...

Page 17: ...sing IP65 IP65 Mechanical data 630822 630823 Material Top Aluminium Aluminium Dimensions Height 60 0 mm 60 0 mm Width 299 8 mm 289 0 mm Depth 40 0 mm 40 0 mm Weight 480 g 350 g PSEN op muting bracket...

Page 18: ...mo PMCprotego PMCtendo PMD PMI PNOZ Primo PSEN PSS PVIS SafetyBUS p SafetyEYE SafetyNET p the spirit of safety are registered and protected trademarks of Pilz GmbH Co KG in some countries We would poi...

Reviews: