38
}
PNOZmulti for safety gate monitoring
Configure the switch in the PNOZmulti Configurator with switch type 3.
}
PSS for safety gate monitoring with standard function block SB064, SB066 or
FS_Safety Gate
}
PSSuniversal PLC for safety gate monitoring with function block FS_SafetyGate
The correct connection to the respective evaluation device is described in the instructions
for the evaluation device. Make sure that the connection is made in accordance with the
specifications in the instructions for the selected evaluation device.
The connections to two evaluation devices are shown on the following pages, by way of ex-
ample:
}
PNOZ s3 and
}
PNOZmulti
PNOZ s3
PSENcode
0 V
24 V
A1
A2
Y32
n.c.
S11
S21
12
22
2
7
8
6
1
3
4
5
PNOZ s3
A1
A2
S22
S12
PNOZmulti
I2
I0
I1
grün
grau
gelb
PNOZmulti
PSENcode
A1
A2
Y32
n.c.
S11
S21
12
22
2
7
8
6
1
3
4
5
A1
A2
0 V
24 V
PSEN cs1.13p ATEX
Operating Manual PSEN cs1.13p ATEX
21097-2EN-13