PNOZ X4
Operating Manual PNOZ X4
19894-EN-07
23
Relay outputs
774735
774736
External contact fuse protection,
safety contacts
In accordance with the standard
EN 60947-5-1
EN 60947-5-1
Max. melting integral
240 A²s
240 A²s
Blow-out fuse, quick
10 A
10 A
Blow-out fuse, slow
6 A
6 A
Blow-out fuse, gG
10 A
10 A
Circuit breaker 24V AC/DC,
characteristic B/C
6 A
6 A
External contact fuse protection,
auxiliary contacts
Max. melting integral
240 A²s
240 A²s
Blow-out fuse, quick
10 A
10 A
Blow-out fuse, slow
6 A
6 A
Blow-out fuse, gG
10 A
10 A
Circuit breaker 24 V AC/DC,
characteristic B/C
6 A
6 A
Contact material
0,2 µm Au
0,2 µm Au
Conventional thermal current
while loading several contacts
774735
774736
Ith per contact at UB AC;
AC1: 240 V, DC1: 24 V
Conv. therm. current with 1 con-
tact
8 A
8 A
Conv. therm. current with 2 con-
tacts
7,5 A
7,5 A
Conv. therm. current with 3 con-
tacts
6,5 A
6,5 A
Times
774735
774736
Switch-on delay
With automatic start typ.
210 ms
210 ms
With automatic start max.
350 ms
350 ms
With automatic start after power
on typ.
240 ms
240 ms
With automatic start after power
on max.
390 ms
390 ms
With manual start typ.
55 ms
55 ms
With manual start max.
350 ms
350 ms
With monitored start typ.
30 ms
30 ms
With monitored start max.
50 ms
50 ms
Delay-on de-energisation
With E-STOP typ.
15 ms
15 ms
With E-STOP max.
30 ms
30 ms
With power failure typ.
55 ms
55 ms
With power failure max.
80 ms
80 ms