Overview
Operating Manual PNOZ mc12p
1003016-EN-03
6
2
Overview
2.1
Scope
}
Expansion module PNOZ mc12p
}
Jumper
2.2
Unit features
Using the product PNOZ mc12p:
Expansion module for connection to a base unit from the configurable control system
PNOZmulti
The product has the following features:
}
Can be configured in the PNOZmulti Configurator
}
Connection for Ethernet POWERLINK (Ethernet POWERLINK V 2 protocol)
}
Station addresses from 1 ... 239, selected via rotary switch
}
The minimum cycle time for an application of 20 Byte Output and 50 Byte Input is
350µs. The minimum cycle time is 500 µs at the maximum PDO size of 240 Byte Input
and 20 Byte Output (the inputs and outputs in this case are viewed from the Managing
Node).
}
24 virtual inputs and outputs on the control system PNOZmulti can be defined in the
PNOZmulti Configurator for communication with the fieldbus Ethernet POWERLINK .
The number of inputs and outputs can be extended to 128. Please note that when the
extended inputs and outputs 24 - 127 are used they have different properties (see doc-
ument entitled "Communication Interfaces").
}
Max. 1 PNOZ mc12p can be connected to the base unit
}
Please refer to the document "PNOZmulti System Expansion" for the PNOZmulti base
units that can be connected.