Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
2-1
2.1
Unit structure
2
Overview
2
2000
Overview
Overview
2-
2.1
Unit structure
2100
Unit structure
2-
2.1.1
Scope of delivery
Scope of delivery
2-
Lieferumfang_Abschl_779 110_Basis_BA
`
Base unit PNOZ m0p
`
Terminator 779 110
2.1.2
Unit features
Unit features
2-
Gerätemerkmale_Verwendung
Using the product PNOZ m0p:
Verwendung/Bildunterschrift_multi_Basis
Base units from the PNOZmulti modular safety system
Geraetemerkmale_Zusatz BA Einleitung
The product has the following features:
Gertemerkmale PNOZ m0p
`
Can be configured in the PNOZmulti Configurator
`
Positive-guided relay outputs:
– 2 safety outputs
Depending on the application, up to PL e of EN ISO 13849-1 and
up to SIL CL 3 of EN IEC 62061
`
Semiconductor outputs:
– 4 safety outputs
Depending on the application, up to PL e of EN ISO 13849-1 and
up to SIL CL 3 of EN IEC 62061
– 1 auxiliary output
`
4 test pulse outputs
`
1 cascading input and output; can also be used as a standard output
`
20 inputs for connecting:
– E-STOP pushbuttons
– Two-hand buttons
– Safety gate limit switches
– Reset buttons
– Light beam devices
– Scanners
– Enabling switches
– PSEN
– Operating mode selector switches
– Pressure sensitive mats
`
Integrated interface:
– PNOZ m0p: Serial interface RS 232
– PNOZ m0p ETH: Ethernet interface
`
Muting function
`
Connectable:
– 1 fieldbus module on the left
– 4 expansion modules on the left