background image

Attachment

Operating Manual PMI 6
1003280-EN-01

29

9

Attachment

9.1

Supported Windows components

The devices work with the operating system "Microsoft Windows Embedded Compact 7";
the following Windows components are supported:

Applications

}

Active Sync (Microsoft Windows Mobile Device Center)

}

CAB File Installer/Uninstaller

}

WordPad

Application and Service Development

}

.NET Compact Framework 3.5

}

Active Template Library (ATL)

}

C Libraries and Runtimes (except OEM Floating Point CRT)

- C++ Runtime Support for Exception Handling and Runtime Type Information
- Full C Runtime
- Standard IO (STDIO)
- Standard IOASCII (STDIO)
- Standard String Functions - ASCII (corestra)

}

Component Services (COM)

}

Lightweight Directory Access Protocol (LDAP) Client

}

Message Queuing (MSMQ)

}

OBEX Client

}

SOAP Client

}

Smart Device

}

String Safe Utility Function

}

XML - MSXML 3.0

- XML Core Services and Document Object Model (DOM)

- XML Query Languages (XQL)
- XML SAX

- XML Minimal Parser

Communication Services and Networking

}

Connection Manager

- Connection Manager All Modules

}

Networking General

- Extended DNS Querying and Update (DNSAPI)
- NDIS Packet Capturing DLL
- NDIS User-mode I/O Protocol Driver
- Network Driver Architecture (NDIS)
- Network Utilities (IPConfig, Ping, Route)

Summary of Contents for PMI 6

Page 1: ...PMI 6 Operating Manual 1003280 EN 01 Operator terminals...

Page 2: ...umentation will be gratefully received Source code from third party manufacturers or open source software has been used for some components The relevant licence information is available on the Interne...

Page 3: ...fety regulations 10 3 3 1 Installation site 10 3 3 2 Measures to protect against interference 11 3 3 3 Supply voltage 11 3 3 4 Operation 11 3 3 5 Maintenance 12 Section 4 Function description 13 4 1 F...

Page 4: ...Start 25 7 2 11 Taskbar and desktop 26 7 2 12 Network servers 26 7 2 13 Internet options 26 7 3 Start mode 26 7 3 1 Automatically copy to system folder windows 26 7 3 2 Batch file PMIStart cmd 26 7 3...

Page 5: ...ead and understood this document The document should be retained for future ref erence 1 3 Definition of symbols Information that is particularly important is identified as follows DANGER This warning...

Page 6: ...n which the product or devices could be dam aged and also provides information on preventive measures that can be taken It also highlights areas within the text that are of particular import ance INFO...

Page 7: ...erate and monitor technical processes 2 1 1 Unit features Capacitive touchscreen Character set Unicode 1 SD card slot Memory 512 MB DDR SDRAM 1 serial interface 1 Ethernet interface 1 CANopen interfac...

Page 8: ...N 01 8 2 2 Front view 1 Legend 1 Touchscreen see Technical details 40 2 3 Scope of supply Operator terminal Retaining clamps Connector plug for power supply Projection stand RJ45 cable for fieldbus ju...

Page 9: ...AUTION The unit is not designed for use in applications with stringent safety require ments e g E STOP The following is deemed improper use in particular Any component technical or electrical modifica...

Page 10: ...ation 3 2 2 Warranty and liability All claims to warranty and liability will be rendered invalid if The product was used contrary to the purpose for which it is intended Damage can be attributed to no...

Page 11: ...central earth point in star form A cable cross sec tion of at least 1 5 mm should be used for the connection Connections should be kept as short as possible 3 3 3 Supply voltage The supply voltage mu...

Page 12: ...1003280 EN 01 12 3 3 5 Maintenance Do not use thinners or organic solvents to clean the unit and touchscreen surface Further information on care and maintenance of the touchscreen can be found in the...

Page 13: ...own on the display and directly influenced via the touchscreen A fieldbus interface CANopen Ethernet e g Modbus and an RS232 interface are available for the transfer of data e g diagnostic data and fo...

Page 14: ...Function description Operating Manual PMI 6 1003280 EN 01 14 7 Fieldbus junction box 8 Supply voltage 24 VDC 9 Serial interface COM1 RS232 10 USB Slave 11 USB Host 1 12 USB Host 2 13 Functional earth...

Page 15: ...operator 5 1 1 Installation site and unit surroundings NOTICE Damage due to heat accumulation To avoid the accumulation of heat a distance of 10 cm 3 94 should be maintained around the device To achi...

Page 16: ...mm 216 8 504 153 6 024 332 13 071 222 8 740 b2 mm h2 mm t2 mm 199 7 835 136 5 354 33 5 1 319 315 12 402 205 8 071 31 5 1 240 b3 mm h3 mm t3 mm 146 6 5 772 101 3 976 45 5 1 791 146 6 5 772 101 3 976 4...

Page 17: ...on of heat a distance of 10 cm 3 94 should be maintained around the device Ensure the information given for the ambient and operating temperatures in the tech nical details is observed IP65 protection...

Page 18: ...Shielding Connect the power cable shield with low impedance to earth Use only shielded data lines For high frequency reasons we recommend that the shielding on the data line cable RS 232 cable is eart...

Page 19: ...24 V DC supply is located on the side of the housing 1 2 3 Fig Layout of supply voltage connector 1 Functional earth 2 0 V 3 24 V DC 6 3 Connection example 1 2 3 4 5 3 4 5 6 Fig Connection example Le...

Page 20: ...earthing bolts housing 6 Data line shield 0 V and are connected internally 6 4 Interfaces Connect X7 and X7 fieldbus to the fieldbus junction cable 6 4 1 RS232 interface COM1 GND DTR TxD RxD DCD RI C...

Page 21: ...card supplied on which the PMI Assistant is installed must be connected to do this When the SD card is not connected the Control Panel is started Further information on the PMI Assistant can be found...

Page 22: ...a password Defining a password Enter a password Enter the password again under Confirm pass word Change password Same as for defining a password Delete password Deselect Ask for master password If you...

Page 23: ...assword protected area This area is protected with a password Remove Remove Control Panel applets from the password protected area This area is not protec ted with a password INFORMATION Add Password...

Page 24: ...ON The ex works setting for the network user is User name pmiuser Password 1234 7 2 3 Date time Setting the date time time zone and winter summer time 7 2 4 Display Setting the background image and ba...

Page 25: ...al settings Regional settings number format currency time date 7 2 8 Storage Manager Format partition memory 7 2 9 System Display modify system properties relationship between program memory file mana...

Page 26: ...led on the external Storage Card using fontreg see Windows CE Shell commands Pilz expansions 35 7 3 2 Batch file PMIStart cmd PMIStart cmd is a CE Shell command batch file which is executed sequential...

Page 27: ...static IP address see Network and dial up 24 7 3 5 Various basic settings Regional settings English currency date time numbers User input language English fixed Input language English keyboard see Reg...

Page 28: ...regular intervals Use a damp cloth to do this NOTICE Make sure the unit is switched off before cleaning it This prevents you from accidentally triggering functions when you touch the touchscreen Clea...

Page 29: ...xception Handling and Runtime Type Information Full C Runtime Standard IO STDIO Standard IOASCII STDIO Standard String Functions ASCII corestra Component Services COM Lightweight Directory Access Prot...

Page 30: ...Server Simple Network Time Protocol SNTP SNTP Client with DST SNTP Server Telnet Server Web Server HTTPD Active Server Pages ASP Support Web Server Administration ISAPI WEBDAV Support Core OS Service...

Page 31: ...CD UDFS File System exFAT File System FAT File System Partition Driver Release Directory File System Storage Manager Control Panel Applet Transaction Safe FAT File System TFAT System Password Fonts T...

Page 32: ...Locale Specific Support English US US Keyboard Internet Client Services Browser Application Internet Explorer 7 for Windows Embedded CE Standard Components Internet Explorer 7 Sample Browser Internet...

Page 33: ...gine Minimal GDI Configuration Minimal GWES Configuration Minimal Input Configuration Minimal Window Manager Configuration Touch Gesture GWES component Shell AYGShell API Set Command Shell Command Pro...

Page 34: ...Separates a command or several commands and sends the output of a command as input for the command that follows file1 Name of the file that includes the output file2 Name of the file that includes th...

Page 35: ...s comments to a batch file RENAME REN Changes the name of one or several files RMDIR RD Deletes a directory SET Sets or removes an environment variable or shows the values of all environment variables...

Page 36: ...tion after formatting with a low formatting rate A Overwrites the standard sizes of memory allocation T Creates a TFAT format Y Confirmation kill Command used to force the completion of a process Synt...

Page 37: ...fo Parameter Description InFile File name temp Temporarily saved the present registration is not overwritten info Status information on the success failure of the ac tion regsave Command used to perma...

Page 38: ...liseconds usrmgr Command used to manage network subscribers Syntax usrmgr a d l user name password gn gd gl gm gat grf Parameter Description a user name password Add or update network subscriber d use...

Page 39: ...Outputs the serial number r Outputs the order number c Outputs the chip set version xcopy Command used to copy files and directory structures Syntax xcopy c h y title sourcedir targetdir Parameter De...

Page 40: ...sh 512 MB 512 MB Real time clock yes yes Removable data medium 265607 265612 Type SD card SD card USB interface 265607 265612 Number of USB Hosts 2 2 CANopen interface 265607 265612 Connection type 9...

Page 41: ...MC EN 61000 6 2 EN 61000 6 4 EN 61000 6 2 EN 61000 6 4 Vibration In accordance with the standard EN 60068 2 6 EN 60068 2 6 Frequency 10 150 Hz 10 150 Hz Acceleration max 1g max 1g Shock stress In acco...

Page 42: ...42 11 Order reference 11 1 Product Product type Features Order No PMI 607 Control Operator terminal 800 x 480 pixel resolution ca pacitive touchscreen 265 607 PMI 612 Control Operator terminal 1280 x...

Page 43: ...p ThE SPIrIT Of SAfETY are registered and protected trademarks of Pilz Gmbh Co KG in some countries We would point out that product features may vary from the details stated in this document dependin...

Reviews: