Supplementary data
Operating Manual PNOZ s30
1001715-EN-15
87
9.2.5.4
Achievable safety level
Safety function
PL in accordance with EN
ISO 13849-1: 2006
SIL CL in accordance with
EN IEC 62061
Speed
Speed range
Direction
Standstill
Position
PL d (Cat. 2)
2
9.2.6
Safety-related characteristic data for operation with a safe rotary
encoder
Safe encoders are certified in accordance with EN 61508, EN 13849 and EN 62061. In or-
der to achieve the safety level stated by the encoder, the safe evaluation device (PNOZ
s30) must normally detect designated errors. Details of the safe encoder's requirements of
the evaluation device can be found in the user documentation for the safe encoder. The en-
coder and evaluation device must be compatible.
9.2.6.1
Permitted encoder types and output signals
Permitted encoder types:
}
Rotary safe encoder
}
Linear safe encoder
Permitted output signals:
}
Sin/Cos output signals 1Vss, reference voltage
}
Sin/Cos output signals 1Vss, differential
9.2.6.2
Safety-related architecture
Sensor
safe encoder
Actuator
SRP/CS
Actuator
SRP/CS
Sensor
PNOZ s30
Logic
+
Diagnostic
SRP/CS
Logic
To calculate the safety function you will need the following data for the "sensor" subsystem
and "PNOZ s30" subsystem:
Sensor
PNOZ s30 subsystem
PL
SIL
PFH (1/
h)
Operating mode
PFH (1/h)
See manufacturer
Monitoring
Safe encoder
2,78E-09