Wiring
Operating Manual PSEN sc M 3/5 series
1005055-EN-02
| 51
6.2.3
Configurable inputs
When using the 8-pin connection, the configurable inputs at PIN 3 and 4 can be used for
the following functions:
}
Restart
}
Reset
}
Restart or reset
}
Zone set switching
}
Muting 1 and 2
}
Dynamic activation of the muting state
When using the 12-pin connection, the configurable input at PIN 3 can be used for the fol-
lowing functions:
}
Restart
}
Reset
}
Restart or reset
}
EDM
}
Zone set switching
}
Muting 1 and 2
}
Dynamic activation of the muting state
6.2.4
Configurable inputs/outputs
When using the 8-pin connection, configurable input/output at PIN 1 can be used for the fol-
lowing functions:
}
Warning output
}
Alarms 1 or 2
}
Muting lamp
When using the 12-pin connection, the configurable inputs/outputs at PIN 7, 9, 10 and 11
can be used for the following functions:
}
Warning output
}
Alarms 1 or 2
}
Muting lamp
6.3
Wiring of the configurations
The configuration of the safety laser scanner PSEN sc M 3/5 series is carried out in
PSENscan Configurator on a configuration PC.
The wiring has to match the specifications in PSENscan Configurator.
6.4
Connect supply voltage and safety controller
The connection for the supply voltage is underneath a memory module. The memory mod-
ule can be uninstalled for simpler connection.
1. Turn the safety laser scanner PSEN sc M 3/5 series for better access to the memory
module.