Safety characteristic data
NOTICE
You must comply with the safety-related characteristic data in order to
achieve the required safety level for your plant/machine.
Operating
Mode
EN ISO
13849-1:
2015
PL
EN ISO
13849-1:
2015
Category
EN 62061
SIL CL
EN 62061
PFH
D
[1/h]
IEC 61511
SIL
IEC 61511
PFD
EN ISO
13849-1:
2015
T
M
[year]
2-ch. OSSD
PL e
Cat. 4
SIL CL 3
7,89E-09
–
–
20
All the units used within a safety function must be considered when calculating the safety
characteristic data.
INFORMATION
A safety function's SIL/PL values are
not
identical to the SIL/PL values of
the units that are used and may be different. We recommend that you use
the PAScal software tool to calculate the safety function's SIL/PL values.
Order reference
Safety light grid
Product type
Features
Order no.
PSEN op4F-
SL-14-015/1
Safety light grid for finger protection, protected field height of 150 mm 631 140
PSEN op4F-
SL-14-021/1
Safety light grid for finger protection, protected field height of 210 mm 631 141
PSEN op4F-
SL-14-030/1
Safety light grid for finger protection, protected field height of 300 mm 631 142
PSEN op4F-
SL-14-036/1
Safety light grid for finger protection, protected field height of 360 mm 631 143
PSEN op4F-
SL-14-042/1
Safety light grid for finger protection, protected field height of 420 mm 631 144
PSEN op4F-
SL-14-045/1
Safety light grid for finger protection, protected field height of 450 mm 631 145
PSEN op4F-
SL-14-048/1
Safety light grid for finger protection, protected field height of 480 mm 631 146
PSEN op4F-
SL-14-054/1
Safety light grid for finger protection, protected field height of 540 mm 631 147