PSEN ma1.3b-28 VA
Operating Manual PSEN ma1.3b-28 VA
22226-EN-03
| 16
INFORMATION
Protect the actuator from unauthorised removal (e.g. via a screw lock or
concealed installation) and from contamination.
}
Prevent self-loosening of the fastening elements of safety switch and actuator.
}
The fastening of safety switch and actuator has to be sufficiently stable to ensure the
proper operation of the safety switch and the actuator.
}
The distance between two safety switches must be maintained (see
).
}
Safety switches and actuators
– Should be kept away from iron swarf
– Should not be exposed to strong magnetic fields
}
Prevent the safety switch and actuator being exposed to heavy shock or vibration.
}
Make sure that the safety switch and actuator cannot be used as an end stop.
}
Circumvention of the safety switch in a reasonably foreseeable manner must be preven-
ted.
}
Please note the installation measures in accordance with EN ISO 14119 for a proximity
switch type 4 with coding level Low.
}
Alignment errors of the guard must not adversely affect the safety function of the guard.
}
The assured operating distance S
ao
and the assured release distance S
ar
must be tested
under real conditions.
}
Do not apply any installation tools (e.g. Pliers) on the surfaces of the switch.
}
Protect the safety switch from UV light or direct sunlight.
}
Any metallic parts (also accessories) must be connected to the equipotential bonding in
case of a risk of charging.
Installation of safety switch
Sensing face
Slide the switch through the hole in the
mounting surface with the sensing face to-
wards the actuator.
Attach the switch using 2 M12x1
hexagonal nuts.