PSEN ma1.3b-28 VA
Operating Manual PSEN ma1.3b-28 VA
22226-EN-03
| 14
Examples for connection to Pilz evaluation devices:
PNOZmulti
Non-Ex area
Ex area
I0
I1
PNOZmulti
PSENmag
T1
T0
PSEN ix1
3
1
2
4
11
12
13
14
3
1
2
4
5+
6
Brown
White
Blue
Black
PNOZ s3
Non-Ex area
Ex area
S21
S22
S11
S12
PNOZ s3
PSENmag
3
1
2
4
5+
6
PSEN ix1
3
1
2
4
11
12
13
14
Brown
White
Blue
Black
Auxiliary contact with LED
The auxiliary contact and the LED indicate the status of the safety contacts.
Actuator in the response range
Safety contacts and auxili-
ary contact
LED
Yes
Closed
lights
No
Open
Off