PIT es Set10u-5ns (AIDA) basic
Operating Manual PIT es Set10u-5ns (AIDA) basic
1004863-EN-03
| 13
Wiring
Please note:
}
Information given in the "
Technical details [
18]
" must be followed.
}
The power supply must meet the regulations for PELV in accordance with EN 60204-1.
}
The maximum cable length depends on the conductor cross section used and the current
requirement of the connected evaluation device. In a maximum current consumption of
100 mA, plus the current of the input circuits of the evaluation device, a rated operating
voltage of 24 V (tolerance: -20 %/+15 %, that is at least 19.2 V) must be available.
}
Only one PIT es Set10u may be used per circuit. However, it may be cascaded with con-
ventional electromechanical E-STOP devices that have only N/C contacts. Note that
when operating a conventional E-STOP device which is in the chain before the PIT es
Set10u-5ns (AIDA) basic, the PIT es Set10u-5ns (AIDA) basic is not electrically supplied
and therefore it is not illuminated.
Preparing for operation
NOTICE
Check the function of the emergency stop device before commissioning for
the first time and then at regular intervals (at least annually).
Assignment of the 5-pin M12 male connector
1
2
3
5
4
PIN
Function
Order no. 400 463
Order no. 400 464
1
Safety contact/test pulse channel 1
Safety contact/test pulse channel 1
2
Safety contact channel 1
Safety contact channel 2
3
0 V U
B
0 V U
B
4
Safety contact channel 2
Safety contact channel 1
5
Safety contact/test pulse channel 2
Safety contact/test pulse channel 2