Supplementary data
Operating Manual PSSu K F EI
1003303-EN-03
| 66
9.1.5.4
Achievable safety level
Monitoring
function
PL of EN ISO 13849-1: 2015
SIL CL in accordance with
EN IEC 62061
SOS-M
SSR-M
SDI-M
SSM
SS1-M
SS2-M
PL d (Cat.2)
2
9.1.6
Safety-related characteristic data for operation with a safe encoder
Safe encoders are certified in accordance with EN 61508, EN 13849 and EN 62061. In or-
der to achieve the safety level stated by the encoder, the safe evaluation device (PSSu K F
EI) must normally detect designated errors. Details of the safe encoder's requirements of
the evaluation device can be found in the user documentation for the safe encoder. The en-
coder and evaluation device must be compatible.
9.1.6.1
Permitted sensor types and output signals
Permitted encoder types:
}
Rotary safety-related encoders
}
Linear safety-related encoders
Permitted output signals:
}
Sin/Cos output signals 1Vss, reference voltage
}
Sin/Cos output signals 1Vss, differential
9.1.6.2
Safety-related architecture
SRP/CS
Sensor
Sensor
safe encoder
Logic
+
Diagnostic
Actuator
PSSu K F EI
SRP/CS
Logic
SRP/CS
Logic
To calculate the safety function you will need the following data for the "sensor" subsystem
and the subsystem "PSSu K F EI":
Sensor
Subsystem PSSu K F EI
PL
SIL
PFH (1/h)
Operating mode
PFH (1/h)
See manufacturer
Monitoring
Safe sensor
2,35E-09