Unit can then be switched on using the ON/OFF
switch. The pressure switch will automatically
start and stop the compressor when the air
receiver drops below or reaches factory set cut-in
and cut-out pressures respectively.
ALWAYS SWITCH UNIT ON AND OFF VIA
PRESSURE SWITCH TO ENSURE THE UNIT
DOES NOT START AGAINST HIGH PRESSURE
TO PREVENT DAMAGE TO UNIT OR PERSONS DO NOT
ATTEMPT TO MODIFY, BYPASS OR REMOVE PRESSURE
SWITCH OR SAFETY VALVE IN ANY WAY.
“TM” OR “K” SERIES ARE DESIGNED TO OPERATE TO
A MAXIMUM PRESSURE OF 10 BAR.
The air receiver is equipped with a safety valve to
release pressure in the event of a pressure switch
cut-out failure. To prevent damage to the unit, do
not attempt to modify, bypass or remove the
pressure switch or safety valve in anyway.
The motor features a manual overload protection
(where fitted). In poor power conditions or motor
over temperature conditions, this overload
protector will cut power to the motor. To reset,
wait for the motor to cool then press reset button.
If problems persist, check for power ratings, faulty
power or poor connections.