5
Assistance may be required to perform this operation.
8
After performing the checks described in step 5, the flat
side of each base unit shaft should be facing towards the
approaching traffic.
When traffic conditions allow, attach a Stop–Go board to
each base unit shaft. The pole of each Stop-Go board
can only be fitted one way onto each shaft. Once fitted,
the Stop side of each board should be facing towards the
approaching traffic:
The flat (keyway) side of
each shaft is the side on
which the STOP sign will
be located.
7
Operate the system through one complete cycle (see the
Operation section on page 6) and check that the shafts of
the base units rotate in the correct sequence.
High wind conditions
In high winds each base unit can be stabilised by placing a
sandbag or similar on the frame outriggers.
8
Once the poles are attached, your installation should be
ready. See the Operation section on page 6.
Align the keyed hole of
the pole with the base
unit shaft. Then slide the
pole all the way down
onto the shaft.
Important: Do not install or operate RoboSign units in bad
visibility or abnormal wind conditions.
Sandbags may be added
for additional stability in
high wind conditions