Caution! 

Shock forces may damage the built-in ceramic element. Please avoid such forces, and 
handle the units with care, otherwise the guarantee will be lost. 

5.  Safety Instruction 

 

Do  not  open  the  units!  There  are  no  user  serviceable  parts  inside  and 
opening or removing covers may expose you to dangerous shock hazards or 
other risks. Refer all servicing to qualified service personnel. 

 

Allow  adequate  ventilation  around  the  units  so  that  heat  can  properly 
dissipate. Do not block ventilated openings or place the units near a radiator, 
oven  or  other  heat  sources.  Do  not  put  anything  on  top  of  the  units  except 
those that are designed for that purpose (e.g. actuators). 

 

Do not spill any liquids into the cabinet or use the units near water. 

 

Do  not  insert  objects  of  any  kind  into  the  cabinet  slots,  as  they  may  touch 
dangerous voltage points, which can be harmful or fatal or may cause electric 
shock, fire or equipment failure. 

 

Do  not  place  any  heavy  objects  on  any  cables  (e.g.  power  cords,  sensor 
cables,  actuator  cables,  optical  cables).  Damage  may  cause  malfunction  or 
shock or fire! 

 

Do  not  place  the  units  on  a  sloping  or  unstable  cart,  stand  or  table  as  they 
may fall or not work accurately. 

 

Work  with  the  units  only  in  a  clean  and  dry  environment!  Only  specially 
prepared units (e.g. actuators) can work under other conditions! 

 

Please use only original parts from 

piezosystem jena

 

piezosystem  jena

  does  not  give  any  warranty  for  damages  or  malfunction 

caused  by  additional  parts  not  supplied  by 

piezosystem  jena

.  Additional 

cables  or  connectors  will  change  the  calibration  and  other  specified  data. 
This  can  change  the  specified  properties  of  the  units  and  cause  them  to 
malfunction. 

 

Piezoelements  are  sensitive  systems  capable  of  the  highest  positioning 
accuracy.  They  will  demonstrate  their  excellent  properties  only  if  they  are 
handled correctly!  Please mount  them  properly  only  at the special  mounting 
points. 

 

Immediately  unplug  your  unit  from  the  wall  outlet  and  refer  servicing  to  qualified 
service personnel under the following conditions: 

 

When the power supply cord or plug is damaged 

 

If liquid has been spilled or objects have fallen into the unit. 

 

If the unit has been exposed to rain or water. 

 

If the unit has been dropped or the housing is damaged. 

 

If the unit is not working properly.

Summary of Contents for 5V10 OEM

Page 1: ...m enables a variety of applications Specials Special circuits are integrated to protect the piezo element from voltage spikes and excessive voltages The main supply voltage is 5V DC A modulation input BNC connector is made for an external signal from 0V to 5V The output voltage is 0V to 150V Design The 5V10 is built in a robust metal casing for easy integration into customer setups Product highlig...

Page 2: ...e noise 3mVRMS 500Hz input impedance 10 kΩ interfaces bare wires protection functions overvoltage protection main supply 5VDC 10 workspace 5 C 35 C 41 F 95 F weight 150g dimensions L x W x H 80x55x20mm 5V10 OEM Piezo Controller Technical data Diagram The diagram shows the typical frequency which can be reached as a function of the capacitance of the piezoelectric actuator and the driving voltage b...

Page 3: ... com Bedienungsanleitung Spannungsverstärker 5V10 Instruction manual voltage amplifier 5V10 Bitte die Bedienungsanleitung vor dem Anschalten des Gerätes sorgfältig lesen Beachten Sie bitte insbesondere die Sicherheitshinweise Read carefully before switching on the power Please see also see instructions for safety using piezoelectric actuators and power supplies Seriennummer Serial Number E ...

Page 4: ... 07745 Jena Germany Tel 49 0 3641 66 88 0 Fax 49 0 3641 66 88 66 e mail info piezojena com http www piezojena com Bedienungsanleitung Seite 3 11 deutsch Instruction manual page 13 21 english Deutsche Version Letzte Änderung 03 12 2007 von DW english Version last change 2007 12 03 by DW ...

Page 5: ...of piezosystem jena 14 3 Declaration of conformity 15 4 Instructions for using piezoelectrical elements and power supplies 16 5 Safety Instruction 17 6 Instructions for checking the function of the system quick start18 7 How to operate the 5V10 19 7 1 Common introduction 19 7 2 Technical data 19 7 3 Initiation 19 7 4 Service 20 7 5 BNC Modulation input MOD 20 7 6 Actuator socket OUT 20 7 7 Cable c...

Page 6: ... com 1 Introduction This manual describes the voltage amplifier 5V10 from piezosystem jena You will also find additional information regarding piezoelectric products Definition All systems from piezosystem jena such as electronics actuators and optical systems are called units 2 Certification of piezosystem jena The company piezosystem jena GmbH has been certified by DIN EN ISO 9001 since 1999 ...

Page 7: ...ration of conformity This certificate is issued for the system PC board voltage amplifier 5V10 manufactured at piezosystem jena GmbH Pruessingstrasse 27 07745 Jena Germany The system as described above herewith complies with the requirements of the European standards as follows EN 50082 DIN VDE 0875 part 11 group 1 part 2 EN 55011 class B declaration issued by piezosystem jena GmbH head of the ele...

Page 8: ...ease note that the acceleration of the ceramic material e g caused by fall down discharging or high dynamic application will occur After excitation of the actuators by a voltage in the upper control range the ceramic will move and generate an opposite high voltage after disconnection Heating of the ceramic material will occur during dynamic operation and is caused by structure conditional loss pro...

Page 9: ...vy objects on any cables e g power cords sensor cables actuator cables optical cables Damage may cause malfunction or shock or fire Do not place the units on a sloping or unstable cart stand or table as they may fall or not work accurately Work with the units only in a clean and dry environment Only specially prepared units e g actuators can work under other conditions Please use only original par...

Page 10: ...have another shape should be parallel each to each other without scratches If there is any damage to the system please contact our local representative immediately If the packaging material is damaged please confirm this with the shipping company Before you switch on the system please check The main voltage supplied in your country is the same as installed for the external power supply not include...

Page 11: ...ss then 3mV it is well suited for positioning in the sub nm range It is well suited for OEM applications 7 2 Technical data Power supply 5V DC no load current mA 100 Dimensions wxdxh mm 80x55x20 Mass g 200 Channels 1 Power W 1 5 Output current mA 10 Output voltage OUT 1 150V adjustable by external modulation Output connector OUT LEMO 0S 302 Inner resistance 10k Noise typical 0 3 mVRMS table 1 tech...

Page 12: ...c qualities of piezo elements are described in the piezoline tutorial in our catalog Do not hesitate to contact our staff if you need further information By increasing the external triggering voltage the motion of the actuator will be done The motion depends on the actuator specs please refer the hysteresis data curve for details 7 5 BNC Modulation input MOD The motion of the actuator may be remot...

Page 13: ...system jena COMPETENCE IN PRECISION 21 piezosystem jena GmbH Pruessingstrasse 27 07745 Jena Germany Tel 49 0 3641 66 88 0 Fax 49 0 3641 66 88 66 e mail info piezojena com http www piezojena com 8 Your notes ...

Page 14: ...piezosystem jena COMPETENCE IN PRECISION 22 piezosystem jena GmbH Pruessingstrasse 27 07745 Jena Germany Tel 49 0 3641 66 88 0 Fax 49 0 3641 66 88 66 e mail info piezojena com http www piezojena com ...

Page 15: ...piezosystem jena COMPETENCE IN PRECISION 23 piezosystem jena GmbH Pruessingstrasse 27 07745 Jena Germany Tel 49 0 3641 66 88 0 Fax 49 0 3641 66 88 66 e mail info piezojena com http www piezojena com ...

Page 16: ...piezosystem jena COMPETENCE IN PRECISION 24 piezosystem jena GmbH Pruessingstrasse 27 07745 Jena Germany Tel 49 0 3641 66 88 0 Fax 49 0 3641 66 88 66 e mail info piezojena com http www piezojena com ...

Reviews: