background image

Please mount them properly only at the special mounting points.

Immediately   unplug   your   unit   from   the   wall   outlet   and   refer   servicing   to   qualified 

service personnel under the following conditions:

when the power supply cord or plug is damaged

if liquid has been spilled or objects have fallen into the unit

if the unit has been exposed to rain or water

if the unit has been dropped or the housing is damaged

6.  instructions for checking the function of the system / quick 

start

When you open the package, please check to make sure all the necessary parts are 

complete (see packing list) and nothing is damaged.

Check the electronics and the actuator for any visible damage:

The top and bottom plate of the actuator (if it does not have another shape) should 
be parallel each to each other, without scratches.

If   there   is   any   damage   to   the   system   please   contact   our   local   representative 
immediately!

If   the   packaging   material   is   damaged   please   confirm   this   with   the   shipping 
company.

The power switch is OFF.

Check that the available main voltage is the same as the label on the amplifiers 
back side.

Connect the power supply.

Connect the piezo-element by using the „OUT“ connector.

Connect the measurement system on the „SENSOR“ connector, if availably.

Switch on the system by using the POWER switch on the front panel.

The green “ON” LED shines permanently. It follows a short selftest of all parts.

Always, when the system is switched on, it slowly goes through the voltage range 
from -20V to 130V.  This is to protect the actuator against depolarisation effects.

Switch on the closed loop by pressing the closed loop feeler in. The “CL” LED will 
shine.

Now you can set the position with the OFFSET potentiometer.

If the “OOR” LED lights up there is an error.

Please switch off the device.

The function check is complete.

21

piezosystem jena GmbH

Pruessingstrasse 27 • 07745 Jena

 Tel ++49 3641 66 88 – 0 • Fax –49 3641 66 88 – 66  • e-mail: 

[email protected]

 • 

http://www.piezojena.com

Summary of Contents for 30V300

Page 1: ...lten des Ger tes Beachten Sie bitte insbesondere die Sicherheitshinweise Read carefully before switching on the power Please see also the safety instructions when using piezoelectric actuators and pow...

Page 2: ...e 16 27 English Deutsche Version Letzte nderung 15 02 2007 von DW English version last change 15 02 2007 by DW Rev Nr 1 0 2 piezosystem jena GmbH Pr ssingstrasse 27 07745 Jena Tel 03641 66 88 0 Fax 03...

Page 3: ...quick start 21 7 description of the digital piezo amplifier 30V300 22 7 1 common introduction 22 7 2 technical data 23 7 3 initiation 24 7 4 service 24 7 5 BNC modulation input MOD 25 7 6 BNC monitor...

Page 4: ...tional information regarding piezoelectric products 2 certification of piezosystem jena The company piezosystem jena GmbH has been certified by DIN EN ISO 9001 since 1999 17 piezosystem jena GmbH Prue...

Page 5: ...bed above herewith complies with the requirements of the European standards as follows EN 50011 DIN VDE 0875 part 11 group 1 class B EN 61000 6 2 declaration issued by piezosystem jena GmbH Dirk W ste...

Page 6: ...rol range the ceramic will move and generate an opposite high voltage after disconnection Heating of the ceramic material will occur during dynamic operation and is caused by structure conditional los...

Page 7: ...oping or unstable cart stand or table as they may fall or not work accurately Work with the units only in a clean and dry environment Only specially prepared units e g actuators can work under other c...

Page 8: ...sentative immediately If the packaging material is damaged please confirm this with the shipping company The power switch is OFF Check that the available main voltage is the same as the label on the a...

Page 9: ...nt panel or by analog signal 0 10V A unique feature of the 30V300 is that it can be used in combination with strain gauge or capacitive feed back sensors without additional modification The amplifier...

Page 10: ...LEMO 0S 250 30V300 LEMO 0S 302 30V300CLE ODU 3pin 30V300nanoX CLE modulation input MOD 0 10V BNC inner resistance 100k OL 50 CLE monitor voltage MON 2 13V BNC 0 10 using CLE Inner resistance 100k out...

Page 11: ...mally 7 4 service The actuator is connected to the amplifier by a LEMO ODU for nanoX socket The potentiometer is used to adjust the level of the output voltage OFFSET The rest position of the actuator...

Page 12: ...control signal must be in the range of 0 10V for example use a function generator There is an internal addition of the MOD signal and the adjusted OFFSET potentiometer 7 6 BNC monitor output socket M...

Page 13: ...sis of the piezo actuator Please take care of settling time when using in dynamic operation 7 9 ERROR LED The ERROR LED signals failure of an operating voltage Or it signals that an operating voltage...

Page 14: ...8 your notes 27 piezosystem jena GmbH Pruessingstrasse 27 07745 Jena Tel 49 3641 66 88 0 Fax 49 3641 66 88 66 e mail info piezojena com http www piezojena com...

Reviews: