background image

The   special   qualities   of   piezo-ceramics   like   hysteresis   and   creep   can   cause 

inaccuracies in the case of nonobservance. These basic qualities of piezo-elements 

are described in the "piezoline" tutorial in our catalog. Do not hesitate to contact our 

staff, if you need further information.

After   switching   ON,   the   green   LED   indicates   “ready   to   operate”.   If   the   OFFSET 

potentiometer is in the maximum counter clockwise position, the actuator is in the rest 

position.   By   turning   the   potentiometer   into   the   maximum   clockwise   position,   the 

maximum   motion  will  be  done.  The  motion  depends   on  the  actuator  specification, 

please refer the hysteresis data curve for details.

The red OOR LED indicates overload or underload. Please avoid over- and underload 

in these cases or switch off the device, if the LED still flashes.

7.5.  BNC modulation input: MOD

The motion of the actuator may be remotely controlled by using this input. The control 

signal must be in the range of 0 ... +10V, for example use a function generator. There 

is an internal addition of the MOD signal and the adjusted OFFSET potentiometer.

7.6.  BNC monitor output socket: MON

30V300 / 30V300nanoX:

The output voltage in ratio 10:1 (-2 ... +13V) is available at this socket and can be 

monitored by using an analogue oscilloscope. Especially while dynamical operation it 

is worth to do it.

Pay   attention   to   the   inner   resistance   of   the   monitor   output,   only   high   ohmic 
measurement (>100k

) devices should be used. The output is short protected, but 

please avoid injected voltages.

30V300CLE / 30V300nanoX CLE:

The measuring voltage (0 … 10V) is available at this socket and can be monitored by 

using an analogue oscilloscope. Especially while dynamical operation it is worth to do 

it.

Pay   attention   to   the   inner   resistance   of   the   monitor   output,   only   high   ohmic 
measurement (>100k

) devices should be used. The output is short protected, please 

avoid injected voltages.

25

piezosystem jena GmbH

Pruessingstrasse 27 • 07745 Jena

 Tel ++49 3641 66 88 – 0 • Fax –49 3641 66 88 – 66  • e-mail: 

[email protected]

 • 

http://www.piezojena.com

Summary of Contents for 30V300

Page 1: ...lten des Ger tes Beachten Sie bitte insbesondere die Sicherheitshinweise Read carefully before switching on the power Please see also the safety instructions when using piezoelectric actuators and pow...

Page 2: ...e 16 27 English Deutsche Version Letzte nderung 15 02 2007 von DW English version last change 15 02 2007 by DW Rev Nr 1 0 2 piezosystem jena GmbH Pr ssingstrasse 27 07745 Jena Tel 03641 66 88 0 Fax 03...

Page 3: ...quick start 21 7 description of the digital piezo amplifier 30V300 22 7 1 common introduction 22 7 2 technical data 23 7 3 initiation 24 7 4 service 24 7 5 BNC modulation input MOD 25 7 6 BNC monitor...

Page 4: ...tional information regarding piezoelectric products 2 certification of piezosystem jena The company piezosystem jena GmbH has been certified by DIN EN ISO 9001 since 1999 17 piezosystem jena GmbH Prue...

Page 5: ...bed above herewith complies with the requirements of the European standards as follows EN 50011 DIN VDE 0875 part 11 group 1 class B EN 61000 6 2 declaration issued by piezosystem jena GmbH Dirk W ste...

Page 6: ...rol range the ceramic will move and generate an opposite high voltage after disconnection Heating of the ceramic material will occur during dynamic operation and is caused by structure conditional los...

Page 7: ...oping or unstable cart stand or table as they may fall or not work accurately Work with the units only in a clean and dry environment Only specially prepared units e g actuators can work under other c...

Page 8: ...sentative immediately If the packaging material is damaged please confirm this with the shipping company The power switch is OFF Check that the available main voltage is the same as the label on the a...

Page 9: ...nt panel or by analog signal 0 10V A unique feature of the 30V300 is that it can be used in combination with strain gauge or capacitive feed back sensors without additional modification The amplifier...

Page 10: ...LEMO 0S 250 30V300 LEMO 0S 302 30V300CLE ODU 3pin 30V300nanoX CLE modulation input MOD 0 10V BNC inner resistance 100k OL 50 CLE monitor voltage MON 2 13V BNC 0 10 using CLE Inner resistance 100k out...

Page 11: ...mally 7 4 service The actuator is connected to the amplifier by a LEMO ODU for nanoX socket The potentiometer is used to adjust the level of the output voltage OFFSET The rest position of the actuator...

Page 12: ...control signal must be in the range of 0 10V for example use a function generator There is an internal addition of the MOD signal and the adjusted OFFSET potentiometer 7 6 BNC monitor output socket M...

Page 13: ...sis of the piezo actuator Please take care of settling time when using in dynamic operation 7 9 ERROR LED The ERROR LED signals failure of an operating voltage Or it signals that an operating voltage...

Page 14: ...8 your notes 27 piezosystem jena GmbH Pruessingstrasse 27 07745 Jena Tel 49 3641 66 88 0 Fax 49 3641 66 88 66 e mail info piezojena com http www piezojena com...

Reviews: