7.2. technical data
7.2.1. suitable casing
dimensions 28 TE / 3HE
BxTxH [mm] standard
195 x 343 x 158 (incl. foot 8mm)
BxTxH [mm] small
164 x 272 x 140 (incl. foot 7mm)
dimensions 42 TE / 3HE
BxTxH [mm] standard
265 x 343 x 158 (incl. foot 8mm)
BxTxH [mm] small
235 x 272 x 140 (incl. foot 7mm)
dimensions 63 TE / 3HE
BxTxH [mm] standard
373 x 343 x 158 (incl. foot 8mm)
BxTxH [mm] small
342 x 272 x 140 (incl. foot 7mm)
dimensions 84 TE / 3HE
BxTxH [mm] standard
480 x 343 x 158 (incl. foot 8mm)
BxTxH [mm] small
448 x 272 x 140 (incl. foot 7mm)
BxTxH [mm] double high
480 x 343 x 290 (incl. foot 8mm)
BxTxH [mm] rack
483 x 272 x 133
table 1: technical data suitable casing
(1 TE = 5.08 mm; 3 HE = 129 mm)
7.2.2. main power supply
main voltage
115V / 60Hz
230V / 50Hz
ENT 40
fuse
2 AT
1 AT
current [A]
2
1
power ENT40 [W]
25
width
14 TE = 71mm
ENT 150
fuse
2 AT
1 AT
current [A]
2
1
power ENT150 [W]
50
width
14 TE = 71mm
ENT 400
fuse
Si1: 1 AT
Si6: 4 AT
Si1: 1 AT
Si6: 2 AT
current [A]
4
2
power ENT400 [W]
100
width
18 TE = 91mm
table 2: technical data main supply
The ENT module was specifically developed to operate the ENV modules of
piezosystem jena
. It is not recommended to be used it in combination with any
other electrical devices. Replace damaged fuses only with same values.