![PiezoDrive PX200 Manual Download Page 5](http://html.mh-extra.com/html/piezodrive/px200/px200_manual_1555825005.webp)
PX200 V2 Manual
5
Rev 1.1, Released, 15-01-2018
4
Output Voltage Range
The desired output voltage range is specified when ordering. The default output range is
0V to +200V (PX200-V0,200). The available voltage ranges and associated current limits are listed below.
Voltage Range
RMS Current Peak Current
Order Code
0 to +200
1.5 A
2 A
PX200-V0,200
0 to +150
2.0 A
4 A
PX200-V0,150
0 to +100
3.1 A
4 A
PX200-V0,100
0 to +50
3.1 A
8 A
PX200-V0,50
-50 to +50
3.1 A
4 A
PX200-V50,50
-50 to +100
2.0 A
4 A
PX200-V50,100
-50 to +150
1.5 A
2 A
PX200-V50,150
-100 to +50
2.0 A
4 A
PX200-V100,50
-100 to +100
1.5 A
2 A
PX200-V100,100
-100 to 0
3.1 A
4 A
PX200-V100,0
-150 to 0
2.0 A
4 A
PX200-V150,0
-200V to 0
1.5 A
2 A
PX200-V200,0
Table 1. Voltage range configurations
5
Output Current
The PX200 has a peak and average current limits as described in Table 1. The RMS current limit defines the
maximum frequency that is achievable with a capacitive load. This topic is discussed in “Power Bandwidth”.
During short-circuit the output current is limited to the rated maximum. The peak current can be drawn for
up to five milliseconds before the output is disabled for three seconds. The average current limit has a
time-constant of ten milliseconds and is reset 50 milliseconds after a previous current pulse. This
behaviour is described in “Overload and Shutdown”