8
Dival SQD-1 - MT 234-E - 02-2020
EN
DESCRIPTION
1.3
Tab. 2 SETTING SPRINGS
Table 2 shows the calibration fields of the different foreseen springs.
- 1 Code n° 64470024BI is for internal relief application (10 -18 mbar)
*
- 2 Code n° 64470031RO is for internal relief application (10 -50 mbar)
*
- 3 Code n° 64470038GI is for internal relief application (30 -100 mbar)
*
* Differential relief valve operating pressure with reference to the nominal outlet pressure (Pd)
SPRINGS CHARACTERISTICS SQD 100 BP
Code
Colour
De
Lo
d
Setting range (mbar)
64470137RO
RED
34
115
1.8
13 - 18
64470024BI
WITE
15
45
1.3
64470068GI
YELLOW
34
115
2
19 - 25
64470031RO
RED
15
40
1.7
64470139NE
BLACK
34
115
2.2
26 - 35
64470031RO
RED
15
40
1.7
64470140MA
BROWN
34
106
2.7
36 - 65
64470031RO
RED
15
40
1.7
64470071GR
GREY
34
118
2.8
66 - 100
64470031RO
RED
15
40
1.7
De = external diameter d = wire diameter Lo = length * = for internal relief valve
Springs
Tab. 2
43
43
42
42
20
20
70
70
73
73
43
43
42
42
Z
Z
20
20
70
70
Fig.2a
Particular spring
Fig. 2b
SPRINGS CHARACTERISTICS SQD 100 MP
Code
Colour
De
Lo
d
Setting range (mbar)
64470141VE
GREEN
34
120
3.2
101 - 170
64470038GI
YELLOW
15
40
2
64470329AZ
LIGHT BLUE
34
111
3.8
171 - 300
64470038GI
YELLOW
15
40
2
De = external diameter d = wire diameter Lo = length * = for internal relief valve
Springs
Tab. 2