![PIETRO FIORENTINI 30051 Operation And Maintenance Manual Download Page 74](http://html1.mh-extra.com/html/pietro-fiorentini/30051/30051_operation-and-maintenance-manual_1555774074.webp)
74
GOVERNORS NOR
TH AMERICA
74
GOVERNORS NOR
TH AMERICA
US
LOW PRESSURE GAS REGULATOR
|
INSTALLATION
|
REV. A
Operation, maintenance and warning manual
7.5.2 - ZERO VERSION ADJUSTMENTS
In case it is necessary to change the calibration values of the Zero version regulator in order to increase or decrease the
zero pressure, proceed as shown in Tab.7.46:
Step Operation
Equipment required
1
Remove the top cap (A) of the regulator.
-
2
Turn the ring nut (B):
• clockwise to increase the downstream pressure;
• counterclockwise to decrease the downstream pressure.
Hexagonal wrench CH11 mm
3
Replace the top cap (A) of the regulator.
-
Tab. 7.46.
GAS
A
B
Fig. 7.22. Zero version operating pressure regulation