Product Description

•   

Easy to use

With the PIECAL 422 you can check & calibrate all 

your thermocouple instruments and measure 

thermocouple sensors. 

•   

Take it without into the shop, plant or field

Carry it without worry - it comes protected with a 

rubber boot and rugged, low profile switch. Easy to 

operate even in the dark areas of the plant with the 

backlit display.

•   Calibrate directly in temperature (°C & °F)

Stop carrying around a millivolt source and 

thermocouple tables. The PIECAL 422 works with the 

thermocouples you use including types J, T, E, K, R, 

S, B, N, G, C, D, L (J-DIN), U (T-DIN) and Platinel II. 

Easily set any value quickly to within 0.1° with the 

adjustable digital potentiometer “ DIAL ” plus store any 

three temperatures for instant recall with the 

EZ-CHECK™ switch.

•   Calibrate quickly with automatic output stepping

Choose between 2, 3, 5, 11 and 21 steps to 

automatically increment the output in 100%, 50%, 

25%, 10% or 5% of span. Select the step time to 

match your system from 5, 6, 7, 8, 10, 15, 20, 25, 30 

and 60 seconds.

•   Compatible with all process instruments

Connect directly to the thermocouple inputs of smart 

transmitters, PLCs, DCS and multichannel recorders 

and verify their outputs or displays. 

•   Measure Thermocouple Sensors

Trouble shoot sensor connections and find broken wires. The PIECAL 422 measures the 

thermocouple in degrees C or F. Secondary display shows the millivolt value corresponding to 

the thermocouple temperature as well as the cold junction temperature measured by the 

calibrator. 

Please contact an authorized sales representative at 800-346-4620 or order at www.Instrumentation.com

Summary of Contents for PIECAL 422

Page 1: ...and Platinel II Easily set any value quickly to within 0 1 with the adjustable digital potentiometer DIAL plus store any three temperatures for instant recall with the EZ CHECK switch Calibrate quickl...

Page 2: ...he HI LO temperature readings which will update as the temperature changes Double click the knob to get into the PIECAL 422 Configuration Mode Use configuration to select C or F T C Type Backlight On...

Page 3: ...cold junction compensator or ice bath is used with the PIECAL 422 BACKLIGHT If BACKLIGHT is ON the backlight will light all the time the unit is powered up For maximum battery life turn the backlight...

Page 4: ...any other device 2 Select READ with slide switch w 3 Place the EZ CHECK switch into the READ position 4 Connect a thermocouple probe matching the type of wire to sensor being measured with min iature...

Page 5: ...the e DIAL KNOB for 6 seconds the word STORE will appear on the display after 3 seconds and continue to press the DIAL KNOB until the word STEPPING appears on the display The word STEPPING will appear...

Page 6: ...to 328 0 0 7 Chromel Constantan Jacket Purple Red Purple 200 0 to 100 0 0 2 328 0 to 148 0 0 4 100 0 to 850 0 0 1 148 0 to 1562 0 0 2 850 0 to 1000 0 0 2 1562 0 to 1832 0 0 4 R 13 3 to 250 0 1 2 1 0...

Page 7: ...2320 0 0 9 3812 0 to 4208 0 1 6 D 1 0 to 50 0 0 6 30 0 to 122 0 1 1 W3 Re W25 Re Jacket White Red White Yellow 50 0 to 1400 0 0 4 122 0 to 2552 0 0 7 1400 0 to 1800 0 0 5 2552 0 to 3272 0 0 9 1800 0...

Page 8: ...60 inches Weight 12 1 ounces including boot batteries Batteries Four AA Alkaline 1 5V LR6 Battery Life 50 Hours Optional NiMh Rechargeable battery kit 120 VAC for North America Only charger four NiMh...

Reviews: